v14.9-r11 - March 23, 2015

Cncbender v14 logo.png


Check.jpg ENHANCEMENT: Direct Axes Jogs Buttons

Direct axes jog buttons were made to work better when a user releases the Jog buttons to better control when the motion stops.

Cncbender v14.9-r11 directaxisjogs enhancement.png



Check.jpg ENHANCEMENT: Cross Slide Check

In previous versions of CNC Bender, the internal logic would not allow the manual jog close of either PRESSURE die or CLAMP die if the Cross Slide input prox for AWAY from die (or in the home position) was active.

This has been changed so that CNC Bender now only examines the Cross Slide input prox for ADVANCED or IN the die active.

This allows for locking the carriage cross slide for little or no movement - with both HOME and ADVANCED proximity switches active at the same time - and still close the dies.

Cncbender crossslide.png



Other Pages