VTube-LASER Cylinder Fit Tolerances
|
Cylinder Surface Points Calculate Cylinder Centerlines
VTube-LASER uses surface points scanned with laser or measured with ball probes to calculate tube centerlines. Regular tube scans assume that the primitive shape to solve for is a cylinder. |
Cylinder Fit Data Window Reports Estimated Maximum Fit Deviations
VTube-LASER reports the accuracy of the centerline fit in the Cylinder Fit Data window. The values are deviations for...
These estimate values are calculated using statistical math. The values are standard deviation x 2, which means that we have 95% assurance that the these values are the maximum deviation. |
Wobble Deviation
To simplify terminology, we say that the highest of the X and Y values is the "wobble deviation". If the centerline calculation is very good, then wobble deviation decreases. If the calculation or fit is poor, then the wobble deviation is too high. |
Default Cylinder Fit Tolerances
To allow VTube-LASER to warn for poor cylinder measurements, it stores tolerances for the allowed deviations during cylinder fit. These values are often setup in the Measure 1 tab of the System Options menu. |
Testing Sounds For Your VTube Computer
Not all computers play these sound files the same way. For example some computer speakers go into an idle shutdown mode that can never start up fast enough to play the short sounds. |
Other Pages
- Back to VTube-LASER
- Back to VTube-STEP