This is a single port Benderlink Ethernet Module that works with Benderlink for Pines to connect a TS-2000 (Pines) control to an Eaton Leonard Vector 1 measuring center.
This device is 100% Eaton Leonard Vector 1 Compatible. Any standard Vector 1 bender port can connect with this module. It is placed near the Vector 1 Laservision measuring center.
Download the PDF Datasheet shown here.
|
|
About the Connections
- One RJ-45 port - This connects to the Ethernet.
- One Military Connector - This connector follows the legacy Eaton Leonard style connection. You can connect standard communications cable with circular connectors at either end.
- One Power Port - Any voltage from 90 to 264 VAC accepted.
|
|
Inside the Module
This is an image of the inside of the module.
- The Advanced Tubular Current Loop board is in the upper left corner. This board makes the connection 100% compatible with Eaton Leonard electronics.
- The Ethernet Serial Device Server is the black box on the right.
- The power supply is on the lower left.
|
|
Example Installation
This is an image of the box installed on a test bench computer running Benderlink for Eaton Leonard, which simulates Vector 1 Laservision communications.
In this application, the module was connected to a PINES 100 running Benderlink for PINES and TS-2000.
|
|
Purchasing
The Benderlink Ethernet Module can be purchased from our Online Store
Other Pages