Wiring: Power to Mitsubishi RESET pin when E-Stop

From ATTWiki
Revision as of 23:55, 24 June 2009 by Mcone (Talk | contribs)

Jump to: navigation, search

Contents

About

This wiring scheme may not exist on older SMT benders. The wiring allows for power to run to the RESET pin on the Mitsubishi drive whenever the Master Power and Safety Relay Contactors are deenergized. This clears the Mitsubishi drives of any faults.

STEP 1: Wire Jump

Wire jump point 22 in M-1 to point 22 in M-2

MitusubishiResetLines01.jpg
MitusubishiResetLines02.jpg

STEP 2: Attach a Power Line

Tap into power by finding wires 2432 at the terminal strip. Run a wire from the strip up to an into point 21 of the M-1 contactor

MitusubishiResetLines03.jpg
MitusubishiResetLines04.jpg

1111

MitusubishiResetLines05.jpg
MitusubishiResetLines06.jpg
MitusubishiResetLines07.jpg

Other Pages