Diagnostic Steps for Master Power On Problems

From ATTWiki
Revision as of 17:31, 29 June 2006 by Jesralian (Talk | contribs)

Jump to: navigation, search

Diagnosing Master Power On Issues

There are a number of diagnostics that you can perform if you experience problems starting the master power on your SMT/ATT CNC Bender. Step through these diagnostics to resolve master power issues.

Check the IP Address of the Operator Station

  1. Press the SYSTEM button
  2. Press the NETWORK INFO tab
  3. Your Operator Station IP Address will be listed

If the Operator Station IP address DOES NOT begin with "192.168.0" then all CNC Bender will not be able to communicate with the Modules and the CNC Bender software will not functional. (CNC Bender uses a Class C network standard, which requires the first three octet values be identical for every device on the network. Most SMT/ATT CNC Benders use a Net Indentifier of "192.168.0")

Ping the IP Addresses of your Modules

  1. Open a command prompt through Windows (Start Button ->Run), then type "CMD" and press "Enter"
  2. Type "Ping 192.168.0.233" (The address of the first module)
    1. A typical successful ping should look like: