CNCProcessor.cfg
From ATTWiki
Contents |
What is It?
The CNCProcessor.cfg file exists in the c:\cnc\configfolder. It contains setup information for the CNC Processor.
Sections
Each of the sections in the CNCProcessor.cfg is set apart with an axis section label like this:
[Intervals]
Properties
Example properties for an axis:
[Intervals] // Maximum Idle Time controls when // the processor will run IdleMachine.runlist // Use it to switch hydraulics OFF after a short time period // if the machine is not in STEP or AUTO mode // This is not necessary in this bender Maximum Idle Time=108000000 // Master Motor Maximum Idle Time controls when // the processor will shut the Master Motor Power OFF // after it senses a period of inactivity. This // inactivity is reset only by jogs and cycles. // 20030425 - This is now controlled primarily in the CONSTANT Run List // which gives us more flexibility than this built-in procedure // set this higher than the value in the constant run list Master Motor Maximum Idle Time=108000000 // How many accumulated parts run before // CNC Processor lubes the machine? Lube Machine At Part Count= 500 Use Bend Count For Machine Lube= 1 Lube Machine At Bend Count= 1000 // How many accumulated parts run before // CNC Processor lubes the machine? Lube Machine At Part Count= 100 [CIO] CIO Name Of Input Clamp Die Close=Input_ClampIsClosed_Begin CIO Name Of Input Pressure Die Home=Input_PressureDieIsHome_End CIO Name Of Input Pressure Die Close=Input_PressureDieIsClosed_Begin CIO Name Of Input Carriage Cross Slide Advance=Input_CarriageCrossSlideIsAdvanced_End CIO Name Of Input Release Button= Input_Release_Button_End CIO Name Of Output Release Illuminate= Output_Release_Illuminate CIO Name Of Boost Bottom Advance= Output_BoostBottom_Advance CIO Name Of Boost Top Advance= Output_BoostTop_Advance CIO Name Of Bend Positive= MOVE_BEND_POS_RELATIVE CIO Name Of Output Machine Lube=Output_MachineLube_Repeat [SOUND] INIT=cncbender_initialized.wav AE=all_axes_enabled.wav AD=all_axes_disabled.wav WRE=warning_range_error_encountered.wav CH=cycle_hold.wav CS=cycle_start.wav MM=manual_mode.wav SM=step_mode.wav AM=auto_mode.wav SMMF=switch_to_manual_mode_first.wav [PRIORITY] Master Loop Priority=10000
Note that remarks may be added to the file with lines preceded by double forward slashes.
// How long does the machine loop output enable?
===Properties Definition===
Read about individual properties:
Lube Machine At Part Count
Use Bend Count For Machine Lube
Lube Machine At Bend Count
--Mcone 23:18, 19 July 2006 (EDT)