End-Scan Using a Ball Probe

From ATTWiki
Revision as of 00:00, 22 June 2012 by Mcone (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Vtube-laser logo.jpg How to perform end-scans with a ball probe.

Vtube-laser 1 73.jpg


Why the End-Scan technique is important

This end-scan method is useful for situations where the only option is a ball probe - or where the Laser cannot reach effectively - but a ball probe can.

Using a ball probe is very precise as long as the tube is properly held with a work holder.

The main drawback is that the tube must be securely mounted without deforming the shape. It must also be touched - thereby potentially moving the tube - which will invalidate most measurements.)


Measure Setup

  • Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3
  • Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS.
  • Set Measure Setup - LASER Tab: Cylinder stripes = 3 to 5
  • Set Measure Setup - LASER Tab: End-scan stripes = 5
  • Set Measure Setup - LASER Tab: Split bend stripes = 5
  • Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types.
  • Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.

How To Use This End-Scan Technique

  • Align the scanner with a slight scissor angle across the end as is shown in the image on the right

  • Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.

  • Consistently place the line across the same area of the tube end from measure to measure.

  • Press the green button until VTube-LASER is finished scanning all the end stripes.

EndWithScissorCloseup.jpg

EndWithScissor.jpg