CNC Bender v12-20120728

From ATTWiki
Revision as of 17:35, 28 July 2012 by Mcone (Talk | contribs)

Jump to: navigation, search

v12-20120728

Cncv12procontrol withteachmode.jpg


Check.jpg Radius Level Shift Command Names Simplified

  • The command names for the radius level shifting were often confusing when moving from HEAD shifters to CARRIAGE shifters. For example, on a head shift machine, AllUp meant radius 1. On carriage shift machine, AllUp meant the top radius (2 or 3).


  • This ambiguity is cleared up by naming the directional valve positions by RADIUS LEVEL number, rather than "UP" or "DOWN".


  • These are the new DEFAULT command names to use:
    • Shift to Radius Level 1
    • Shift to Radius Level 2
    • Shift to Radius Level 3
    • Shift to Radius Level 4
    • Shift to Radius Level 2 From 1
    • Shift to Radius Level 2 From 3
    • Shift to Radius Level 3 From 2
    • Shift to Radius Level 3 From 4

Check.jpg Radius Level Shift Command Names Can Be Changed

  • The radius level COMDEF names can be configured to custom names in the Low Level COMDEF Names Cross Reference menu.

400

Other Pages