VTube-LASER v1.86
Revision 1.86
|
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCED: Bender Number Stored in Project
The bender number selected for communications is now stored in the project file for recall later. The assumption is that a given part is often bent on the same bender.
|
NEW: Project Open and Save Path is Stored
The most recently used project file open and save paths are now stored and used for future open and saves.
|
ENHANCED: Measure Process Menu Reorganized
To help ease the workflow in VTube-LASER, the Measure Tube-Cylinder panel is moved to the top of the Measure Process menu.
|
|
ENHANCED: Straight Count Controls Moved to Setup Menus
ENHANCED: AddisonMckee Mark IV EXTENDED Communications
Some AddisonMckee Mark IV benders require that its custom teach mode data be returned in the communication data during an automated bender correction from VTube. For benders that require this data during corrections from VTube, if this data is not found by the control, then a small message box will appear with a message that the incoming data is not AddisonMckee Mark IV data, and the correction data will be ignored. To solve this problem, VTube-LASER now takes in and stores this data during a RECALL from the bender. When VTube sends corrections back to the bender, it includes this custom data in the transmission. This means that a RECALL is required before corrections are made to this kind of control.
|
ENHANCED: Bender Data Setup Menu Changes
A new CLEAR the Adjustment is added to allow operators to clear the Adjustment Grid. |
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor