VTube Intersection Point Tolerances

From ATTWiki
Revision as of 19:46, 13 August 2014 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-laser logo.jpg XYZ Intersection Tolerances

Vtube-laser 1 73.jpg


How the Tolerances Work



The XYZ intersection tolerances are designed to allow you to qualify a part using +/- tolerances to the intersection.

The intersection tolerances are based on values are that follow the three axes in a coordinate system. Since the tolerances measure along the axes, as of version 1.93, these tolerances can be positive or negative to also indicate a direction.

Vtube-laser xyz intersection tolerances inspection grid.png

Set the Tolerances in Inspection Data Menu

You can set these tolerances in two places in VTube-LASER. The first place is in the Inspection Data menu.

Click on the Change Grid Setup button until you see the tolerances in the grid like we show in the image on the right.

Then select and change any tolerance value. The grid will allow you to edit only the tolerances.

Vtube-laser inspectionresults overall xyz intersection with tolerances.png

Or Set the Tolerances in Expanded Windows

The second place to edit the value is in the VTube-LASER Expanded Window.

Click on the Expanded Window button to display the Expanded Window, and then make changes to the tolerances there.

The benefit of the Expanded Window is that you can view all the tolerances at the same time.

Vtube-laser-1.91-expanded xyz intersection deviation edit tolerance.png

Vtube-laser-1.91-expanded-xyz deviation grid.png

Setting All The Tolerances At The Same Time

The intersection deviation grids allow you to set the default tolerance to every value in a row, column, or even the entire grid using a popup menu

To use this feature, single click on a tolerance value, the right click and choose the action.

Vtube-laser intersectiondevation tolerances popup.png


Other Pages