VTube-LASER and VTube-STEP can communicate with bender controls using the Supravision Network protocol.

VTube-STEP can SEND data to benders using the protocol. VTube-LASER can SEND and RECALL data to/from benders for full corrections loops.

Follow this guide to setup the VTube for communications with benders using the Supravision Network protocol.

Vtube 1.99 BendPro Connection.png


VTube-STEP Setup for Supravision Network Communications

Use the VTube-STEP Bender Output menu to setup and send new part data to a bender using Supravision Network protocol.

Go to the SV Network tab and choose the bender number and set the shared path where Supravision Network communications occurs.

  • The Supravision Network protocol uses a bender number (from 1 to 99) to indicate which bender should pickup and use the Supravision file that is being saved by VTube-STEP to the file path in the network box.

  • At the bender control, set the protocol to Supravision Network, set the bender number, set the path, and turn on communications if this is required.

Vtube-step 1.99 supravision network.png

VTube-LASER Setup for Supravision Network Communications

VTube-LASER uses a Benderlink grid to setup the communications protocol for each bender. The grid is in Setup Options, Measure 2, Setup Benderlink Options menu.

In the Benderlink options menu, choose the bender to edit by selecting the cells in the bender row you want to setup.

  • Set the bender name (this is for showing the bender name in the user interface only).

  • Set the protocol by choosing Supravision Network.

  • Set the NetPath where files will be shared.

  • Skip the ComPort setting because it has no application to this protocol.

  • Set the timeout to from 5 to 10 seconds for most controls. This will give the control a few seconds to respond to requests.

  • Set the Part Name Match to Yes or No. If the option is set to Yes, then a mismatched part name in the data will cause VTube-LASER to warn of a part name mismatch while receiving data.

  • If the network location server has a fixed IP address, then the location can be pinged to prove that the network path is currently available before VTube attempts to save files in the network path.

  • Finally, set the number at the bender. This allows any bender in any row to have any bender number. Remember: If all Supravision Network-based benders share the same network path, then each bender should be assigned a unique bender number.

Vtube setupbenderlinkoptions.png

Vtube setupbenderlinkoptions 02.png


VTube-LASER Supravision Network Communications

To communicate with a bender when using VTube-LASER, switch to the Bender Setup menu (see the navigation pane on the right), then follow these steps.

  • If the bender control needs to be placed into communications mode, then do that now.

  • Back at VTube-LASER, set the bender number on the top.

  • If the Bender values in the blue columns are all zeros, then use the Setup this Window menu on the right to copy master data into this menu.

  • To send new data out to the bender, use the Setup the Bender button on the far right and press one of the Send buttons.

  • To perform a correction to the bender, use the Bidirectional Communication menu on the right. Press the RECALL then the AUTO SEND to fully correct the bender.

Vtube-laser 1.99 bendersetupmenu.png