Recommended VTube-LASER Laser Scanner Settings

From ATTWiki
Revision as of 19:08, 25 December 2015 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtube-laser logo 1.96.png

Vtl screen hd scanner without logo.png



Ideal Setup for HD Scanner in VTube-LASER

The HD blue line scanner has increased capabilities in point density that causes us to recommend some unique settings in FARO scanner setup. These settings work very well in VTube-LASER.

You must be connected to a FARO arm to perform these steps.

STEP 1

In VTube-LASER window click on Scanner Algorithm label above the viewport window.

Vtube-laser v2.2 leftmouseclick scanneralgorithm label.png

STEP 2

Set the Scan Rate to 1/1.

  • This value will allow the laser stripes to come into VTube-LASER as quickly as the driver can send them.

Set the Scan Density to 1/16

  • This value will reduce density of the points in the laser line. Since VTube-LASER removes some of points with a "points per stripe limit" filter, it works faster if the FARO driver removes some of those points in advance. Both scanning and calculation can be many times faster.

Vtube-laser v2.2 farol llp scan rate density.png

STEP 3

Select the correct ball probe then press OK.

This step will cause the FARO driver to report back to VTube the new probe. The FARO driver should always remember the last ball probe that you set to "Current Probe" in the pulldown box. This is true even if you shutdown VTube-LASER and the FARO arm.

Vtube-laser v2.2 faro compensation menu.png

STEP 4

Press the Close button in the FARO Arm Utilities window.

Vtube-laser v2.2 armutilities dialog press close.png

STEP 5

Observe that the new ball probe selection will appear in the Arm grid.

Vtube-laser 2.2 measuresetup menu 6mmball.png