VTube NUMALLIANCE Bender Correction

From ATTWiki
Revision as of 23:29, 25 November 2019 by Mcone (Talk | contribs)

Jump to: navigation, search

VTube-LASER AssemblyOverModel.png RightOrangeArrow.png Numalliance Splash.png

This page describes how to use VTube-LASER to correct NUMALLIANCE benders.



Back to VTube-LASER

Contents


NUMALLIANCE CORRECTIONS

VTube-LASER has an export option for NUMALLIANCE MES files that are used to correct the NUMALLIANCE benders.

Note: NUMALLIANCE benders only require the measured data for corrections.

Measure the tube in VTube-LASER, then send the MEASURED tube data to the bender control, and it will then perform the correction.

Follow the steps below.

NumallianceCorrectionsSlide1.png



STEP 1

Press the Bender Setup button. (These steps assume that you have measured the tube and have setup VTube-LASER with the NUMALLIANCE protocol.)

Numalliance1.png



STEP 2

Set the bender number. It should say NUMALLIANCE like shown here.

If the data in the window is not correct, then import the data from the main VTube-LASER memory by clicking on "Setup this Window" then clicking on "Copy Master LRA to Setup LRA".

In the "Correct the Bender" menu, click on Auto Send.

A save file dialog will open and allow you to name the MES file on a thumb drive or on the network. This file will be imported into the NUMALLIANCE control.

Numalliance2.png



STEP 3

At the NUMALLIANCE control, press the CAD button.

NumallianceCADbutton.png



STEP 4

Press the XYZ/LRA button.

NumallianceXYZLRA.png



STEP 5

Press the File button.

Press the Import corrections button.

NumallianceFileAndImport.png



STEP 6

Open the file from VTube.

NumallianceOpenMESfile.png



STEP 9

Import the file into the NUMALLIANCE control.

NumallianceCorrectionSlide10.png