How to Ensure Good End Scans in VTube-LASER
From ATTWiki
|
Contents |
REPEATABLE END SCANS
Repeatability issues on the ends is the most common problem in GR&R tests. Fortunately it is also the easiest to fix. It involves training users to perform a visual check of the model in the viewport after VTube calculates the end points. |
Use Visual Feedback
In VTube-LASER, operators can use visual feedback to ensure that end point projections are good. This is an example of the the end point projected so that it is in line with the end wall. |
Finding The End Wall
VTube-LASER shows the cloud of points used for the end scan as well as the blue cylinder and the orange end point. |
Visually Align The End Point
The orange end point will always be somewhere along the centerline of the blue cylinder. After the orange end point is projected, an operator can visually confirm that the orange point has been projected along the centerline to the correct location by imagining lines relative to the end scan point cloud like shown in this image. |
An Example of a Scan to Reject
In this case, we put a camera stand near the end of the tube to create an example scan that is not a good one. |