Tutorial: How to Change the Tube Support Point
From ATTWiki
Follow these steps to change the tube support point:
- STEP 1
Enter the low level menu of CNC Bender.
- STEP 2
Select the Init Axes tab.
- STEP 3
Find the line in the Init Axes configuration that looks like this:
// Set the Feed Programmable Limit Switchs
FeedAxisPLS5 = LSL0:1500.1, LSU0:3000
FeedAxisPLS4 = LSL0:1, LSU0:1499
- STEP 4
Close CNC Bender software.
- STEP 5
Close the CNC Bender Loader when it reappears. The newer non-button versions of this loader will unload if you right-click on them.
- STEP 6
Plug the USB drive into a USB port on the CNC Bender operator station. The older systems have USB ports inside the operator station. Some have USB ports installed on the enclosure. Newer Magelis controls feature a USB port on the front of the PC Panel bezel.
- STEP 7
Run the setup program. You will need to enter the password to install the software.
- STEP 8
When the setup program is complete, remove the USB drive using the safe removal procedure. (See Safely Remove a USB Drive)
- STEP 9
Run the CNC Bender Loader by finding it in your START/All Programs/Startup menu.
- STEP 10
Run CNC Bender by pressing on the Loader
BACKUP
The CNC Bender setup will create a backup of files replaced when you run this program. A backup folder contains the name "backup" and is always placed in the c:\cnc folder.