CNC Bender v10-20080319
CHANGES to CNC PROCESSOR
New - Automatic Transformation of 2031 MODBUS Commands to 2032
The 2032 command is a new type of incremental move command that instructs the controller to move the axis a relative motion from its current position. (2031 moves from the goal position, which may not be the current position)
This resolves an issue with direct axes jogging where an axis stops moving at a hard-stop, but the controller continues to track the position as if the axis is still moving. MOBUS command 2032 overcomes this potential problem.
Only controls upgraded by SMT technicians can use the 2032 command. If this feature is enabled before the control firmware is updated the incremental or relative motion will not work properly.
The transformation is enabled and setup in the CNCProcessor.cfg file in a Modbus section that looks like this:
[Modbus] Transform 2031 Enabled= 1 Transformed 2031= 2032
The text in these fields before the "=" must appear exactly as shown above for the values to take effect in CNC Processor.
The "Enabled = 1" indicates that the feature is enabled. Set th value to 0 to disable the feature.
New - Internal Process List Queuing To Resolve Overlapping Processes
When a motion fault (like a timeout) occurs in CNC Bender, the software runs the Post Fault and Post Halt process lists. However, those process lists could, in certain circumstances, be overtaken by the De-Initialize process list. When this occurs, the Post Fault or Post Halt lists are supplanted mid-operation by the list that is overrunning. The initial lists never finish their process, confusing the logic in CNC Processor which often creates erratic motion.
This resolves that issue by using a new queuing process where these process lists (like De-Initialize) are made to wait in the queue behind earlier running or already waiting process lists.
This queuing effects these process lists:
- All Controlled Jogs
- De-Initialize
- Post Halt
- Post Fault
- Home Machine
- Post Home Machine
The Initialize Process List
The only maintenance process list that is not made to wait in a Queue is the Initialize process list, which should always run first after the Cycle Start button is pressed.