CNC Bender v11-20080823
From ATTWiki
CHANGES to CNC PROCESSOR
Handle Run Buttons Anti-Tie Down Internally
Edge Trigger logic is used to require a button to be released then pressed before it is considered activated. This is usually applied where it is unsafe to allow a button to be continuously pressed (without release) for machine operation.
Run button inputs require special handling with Edge Trigger logic, so if Edge Trigger logic is enabled for either the left or right run button inputs, then CNC Processor ignores the "require edge trigger" setting for those two inputs so that the anti-tie down logic is handled internally.
If the "require edge trigger" is set to ON in either of these inputs, then Processor will report in the log when CNC Bender is loaded. The message displayed in the log will be:
Run Button Edge Triggers Are Switched OFF - Handling Internally in CNC Processor
Other Pages
- Back to CNC Bender
- Back to CNC Bender Software Updates
- Read about Push Bending
- Read about Push Bend Profile Tables