Configuring Machine Lube Settings
From ATTWiki
Contents |
In the CNCProcessor.cfg File
The CNCProcessor.cfg contains the property values that allow you adjust the Machine Lube setup in CNC Bender. For more about the config file, see CNCProcessor.cfg.
Configuration Section: "Machine Lube"
The settings in this file are separated by sections with section names in square brackets. This is an example:
[Machine Lube] Machine Lube Duration=5000 Lube Machine At Bend Count=100 Pulse Machine Lube Pump=1 Watch For Machine Lube Complete Input=0
The four values above control the machine lube features in CNC Bender.
Value 1: "Machine Lube Duration" | Read how to set the Machine Lube Duration |
Value 2: "Lube Machine At Bend Count" | Read how to set the Lube Machine At Bend Count |
Value 3: "Pulse Machine Lube Pump" | Read how to set the Pulse Machine Lube Pump |
Value 4: "Watch For Machine Lube Complete Input" | Read how to set the Watch For Machine Lube Complete Input |
Other Pages
- Back to CNC Bender Technical Notes
- See Auto Lube for details on how to test the Auto Lube system
- See Configuring Machine Lube Settings
- See CNCProcessor.cfg