CNC Bender v11-20090827
From ATTWiki
NEW - CYCLE HOLD for Secondary Processes
In previous versions, "[CYCLEHOLD]" had no effect inside secondary processes that control devices around the bender. Now hoppers and side loaders can put the entire cell into the regular cycle hold state.
This is a snippet from a secondary processlist that shows this feature in action:
[IF] AND, input=not(Input_AutoLoader_PartPresent_End), input=Input_AutoLoader_PartPresent2_End, output=not(Output_AutoLoader_GripperClose_Constant) [Immediate_Message] AUTOLOADER PART NEST JAMMED - Entering CYCLE HOLD [CYCLEHOLD] [END]
ENHANCED - AutoLoader Timeout is Tied to Robot Timeout
The Robot Timeout value in the Low Level dynamic options is now used to control the AutoLoader timeouts.
Other Pages
- Back to CNC Bender
- Back to CNC Bender Software Updates
- See Cycle Hold
- See Hopper Logic
- See Processlist
- See Secondary Processlist