Difference between revisions of "CNC Bender ProControl 10.0.6.2"
(→NEW: Automatic Shutdown for BENDER SYSTEM) |
|||
(13 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | |||
[[Image:Cncbender_splash_10_0_6_2.jpg|right|350px]] | [[Image:Cncbender_splash_10_0_6_2.jpg|right|350px]] | ||
Line 14: | Line 13: | ||
=NEW: RELOAD Setup= | =NEW: RELOAD Setup= | ||
− | [[image:cncbender_reload_setup.jpg| | + | [[image:cncbender_reload_setup.jpg|450px]] |
This feature is added to the Utility menu. It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software. | This feature is added to the Utility menu. It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software. | ||
Line 29: | Line 28: | ||
=NEW: Automatic Shutdown for BENDER SYSTEM= | =NEW: Automatic Shutdown for BENDER SYSTEM= | ||
− | [[image:Cncbender_automaticshutdown.jpg| | + | [[image:Cncbender_automaticshutdown.jpg|450px]] |
− | A new Automatic Shutdown process is initiated when a loss of TCP/IP connection to any top hat module around the bender is | + | A new Automatic Shutdown process is initiated when a loss of TCP/IP connection to any top hat module around the bender is discovered. This allows for a much-improved and smoother bender shutdown process. |
Line 62: | Line 61: | ||
# Press the E-stop on the operator station. | # Press the E-stop on the operator station. | ||
# Power down the bender. | # Power down the bender. | ||
− | # CNC Bender will sense a loss of TCP/IP communication and propose a shutdown in 15 seconds. This shutdown can be overridden by the operator. | + | # CNC Bender will sense a loss of TCP/IP communication and propose a shutdown in 15 seconds. (This shutdown can be overridden by the operator if he decides to stop the shutdown of CNC Bender.) |
− | + | ||
− | + | ||
# The CNC Bender UPS (inside the operator station) will initiate Windows shutdown after 60 seconds of loss of power. (This has been verified for both Windows 2000 and Windows XP) | # The CNC Bender UPS (inside the operator station) will initiate Windows shutdown after 60 seconds of loss of power. (This has been verified for both Windows 2000 and Windows XP) | ||
# The CNC Bender UPS will power down 90 seconds after Windows was shutdown. | # The CNC Bender UPS will power down 90 seconds after Windows was shutdown. | ||
+ | |||
+ | |||
+ | [[image:Minuteman mn350.jpg|right|400px]] | ||
(Total shutdown time: Approximately 3 minutes) | (Total shutdown time: Approximately 3 minutes) | ||
Line 80: | Line 80: | ||
</td> | </td> | ||
<td bgcolor="#e3e4f5"> | <td bgcolor="#e3e4f5"> | ||
− | The AUTO HEAL process was designed to attempt to re-connect any lost TCP/IP connection between the operator station and the various modules around the bender. | + | The AUTO HEAL process was designed to attempt to re-connect any lost TCP/IP connection between the operator station and the various modules around the bender. |
+ | <br><br> | ||
+ | This feature had only limited benefit, so it was replaced by the AUTO SHUTDOWN feature that senses if the bender power has been shutdown at the electronics enclosure. | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 92: | Line 94: | ||
<td bgcolor="#e3e4f5"> | <td bgcolor="#e3e4f5"> | ||
RECOMMENDED SETTINGS FOR POWERCENTER Software | RECOMMENDED SETTINGS FOR POWERCENTER Software | ||
− | [[image:Minuteman_powercenter.jpg | + | <br><br> |
+ | [[image:Minuteman_powercenter.jpg|300px]] | ||
+ | |||
# Shutdown Windows in 60 seconds | # Shutdown Windows in 60 seconds | ||
# Begin verbal warning in 30 seconds | # Begin verbal warning in 30 seconds | ||
# Repeat verbal warning every 10 seconds | # Repeat verbal warning every 10 seconds | ||
+ | |||
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 22:13, 19 March 2007
REVISION Information
10.0.6.2, March 15, 2007
NEW: RELOAD Setup
This feature is added to the Utility menu. It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software.
There are circumstances where changes to values in low-level configurations may normally need a reboot of the CNC Bender software. Examples are changes to the Axis Configuration, Module configuration, and Processlist configration. This new feature allows operators to reload the configuration without actually rebooting CNC Bender.
NEW: Automatic Shutdown for BENDER SYSTEM
A new Automatic Shutdown process is initiated when a loss of TCP/IP connection to any top hat module around the bender is discovered. This allows for a much-improved and smoother bender shutdown process.
NEW: User Interface SKINS
CNC Bender now allows users to enter the User Interface tab menu in the Low Level menu.
- Enter the Low Level menu
- Choose the User Interface menu
- Choose a skin name from the skin list (Click on the image at the right to see the list of skins)
This shows three examples of different skins in CNC Bender ProControl:
REPAIRED: Pressure Die Boost Inhibit Zones Logic for Multi-Bending
The multi-bending feature allows for retracting the pressure die multiple times during one bend. The pressure die inhibit zone logic would not always work correctly when the multi-bending feature was enabled. This a logic issue has been repaired.
NEW: CNC Bender Speed Control Redesigned
The new CNC Bender speed control is designed to be easier to use than the older spin buttons. This fixes the issue of operators having difficulty pressing the up-down arrows to control the speed.
NEW: Dynamic Options Redraw Redesign
The Dynamic Options controls have been redesigned so that they no longer flash on the screen when moving the option selection up or down in the Dynamic Options list.
REPAIR: Axis Monitor Dialog Display
The Axis Monitor dialog no longer displays and freezes on the screen at CNC Bender startup.
NEW: PreCommands for LOAD or START
These new Dynamic Options allow operators to enable a custom COMDEF (Command Definition) before either the Load Position or the Start Position moves in the Process List for bending. Use this feature to enable/disable actuators just before either of these moves occur in the Process List.
User-Definable and therefore Flexible
Because these reference general COMDEF files (PreCommand_LoadPosition and PreCommand_StartPosition) the motion or action that these PreCommands perform can be adjusted to fit the application by anyone familiar with using the COMDEF.exe and CIO.exe programs.
For example, it would take only a few minutes to reconfigure CNC Bender to actuate several new outputs, then watch for any number of inputs in either of these COMDEF commands. No new programming from Advanced Tubular is required to adjust these commands.
PreCommand Load Position Enable / Disable |
Enable this option to insert the PreCommand_LoadPosition COMDEF in the process list immediately before the Feed axis move to Load position command is issued in the list.
|
PreCommand Start Position Enable / Disable |
Enable this option to insert the PreCommand_StartPosition COMDEF in the process list immediately before the Feed axis move to Start position command is issued in the list.
|