(STEP 5: Measure The Part)
(STEP 5: Measure The Part)
Line 111: Line 111:
 
Now scan the center of the inside.  Be sure that at least one point in one stripe passes the center inside of the bend.  If you are not sure, then release the green button and look at the screen to see if you have points and surfaces that appear to be in the right place.  If you know you've scanned the center, then press the RED button to move on to the next straight.<br><br>
 
Now scan the center of the inside.  Be sure that at least one point in one stripe passes the center inside of the bend.  If you are not sure, then release the green button and look at the screen to see if you have points and surfaces that appear to be in the right place.  If you know you've scanned the center, then press the RED button to move on to the next straight.<br><br>
 
'''If you want to see a Split Bend measured performed then see video 40 in [[VTube-LASER_Videos]].'''<br><br>
 
'''If you want to see a Split Bend measured performed then see video 40 in [[VTube-LASER_Videos]].'''<br><br>
 +
[[image:vtube-laser_v2.2-splitbendvideo40.png|300px]]<br><br>
 
Press FINISH and APPLY Measure when the measurement is completed.
 
Press FINISH and APPLY Measure when the measurement is completed.
 
</td>
 
</td>

Revision as of 21:10, 9 February 2016

Vtube-laser logo 1.96.png

Vtl screen hd scanner without logo.png


How to Reverse Engineer a Part Using Split Bend

The Split Bend feature allows you to accurately measure bends that equal or exceed 180 degrees.

Split Bend setup is controlled in the Bend Setup tab of the Master Tube menu in VTube-LASER, and in the Bend Setup tab in VTube-STEP. Both modes of VTube allow you to configure Split Bends.

To turn a Split Bend ON for a straight section, you enter the Split Bend window and select the straights that should be treated as Split Bends.

Vtube-laser v2.2 master with splitbend.png

STEP 1: Enter PART SETUP Data

Enter the Part Setup data for the new part. Especially enter the PART NUMBER and DEFAULT RADIUS. (You can measure the radius if necessary in Measure Process.)

Vtube-laser v2.2 default radius.png

STEP 2: Populate the MASTER TUBE DATA Grid

Since the Split Bend feature creates a grid based on the number of straights in the MASTER data, it is important to set the number of points that you will be measuring in the reversed tube.

Enter the MASTER TUBE menu, set the point count (which is two more than bend count), and press the SET button. The XYZ values will be filled with zeros like this:

The radius values were automatically filled with the DEFAULT RADIUS value from the PART SETUP menu.

Vtube-laser v2.2 set master point count.png


STEP 3: Configure the Split Bend Window

The Split Bend window is on the Bend Setup tab in the MASTER TUBE menu. Click into that window.

Vtube-laser v2.2 enter split bend window.png

In the Split Bend window, set any straight that will be treated as a Split Bend.

Close the window. VTube will now understand which straight to treat as a Split Bend during measuring.

Vtube-laser v2.2 split bend window straight selected.png


STEP 4: Configure the Measure Setup

Enter the Measure Setup menu LASER tab, and set the Split Bend settings:

  • Arrow 3: Activate the LASER scanner for Split Bends.
  • Arrow 4: Set the number of allowed STRIPES to 250 for Split Bends.

Vtube-laser v2.2 lasersetup splitbend.png

In the SEPARATION tab menu, check the following settings:

  • Arrow 2: Set the SPLIT BEND Scan Type to DISTANCE.
  • Arrow 3: Set the SPLIT BEND Scan Distance to 0.039" (or 1 mm).

Vtube-laser v2.2 separationsetup splitbend.png.png

STEP 5: Measure The Part

This step is identical to regular reverse-engineering measuring.

When you arrive at the split bend to scan, VTube-LASER will make a special sound and tell you to scan the OUTSIDE of the bend. Scan as much data as you want - up to 250 stripes. The goal is to be sure that at least one point in one of the stripes touches the highest point of the outside of the bend. So you can take as many stripes of data as you want - VTube will take them all in without a problem.

During scanning, release the green button, and look at the screen. You should see a large area of surfaces that pass the point of the outside of the bend. Press the RED button if you are finished scanning the outside and have not come to 250 stripes.

Now scan the center of the inside. Be sure that at least one point in one stripe passes the center inside of the bend. If you are not sure, then release the green button and look at the screen to see if you have points and surfaces that appear to be in the right place. If you know you've scanned the center, then press the RED button to move on to the next straight.

If you want to see a Split Bend measured performed then see video 40 in VTube-LASER_Videos.

Vtube-laser v2.2-splitbendvideo40.png

Press FINISH and APPLY Measure when the measurement is completed.

Vtube-laser-v2.2 measureguide cylindricaltube.png

STEP 6: Choose Build Measured Tube Data Only

Because the MASTER data row count is greater than zero, the Measurement Complete window will offer to allow you to ALIGN the measured tube.

However, do NOT align at this point - because there are only ZEROS in the MASTER Data fields.

Rather - press the Build Measured Tube button.

Vtube-laser-v2.2 Build MeasuredTueDataOnly.png

The new measured tube will appear as a blue tube like this.

Vtube-laser-v2.2 MeasuredTubeSplitBend.png

STEP 7: Copy Measured to Master

Copy Measured to Master Data in the Data Handling menu. This will overwrite the MASTER data ZEROS with the MEASURED tube data.

When you press this button, the MEASURED data will be copied to the MASTER data menu and the MASTER data menu will display automatically.

Vtube-laser v2.2 copy measured to master.png

STEP 8: Optional Reset Origin to Zero

Some customers prefer to translate the new MASTER data so that the first point is at 0,0,0.

Vtube-laser v2.2 reset origin to zero.png

STEP 9: View the New Master Tube

View the new MASTER tube by switching the display of the Master tube on, then redrawing and zooming all.

In this case, the MASTER tube is translated in space from the measured tube because the coordinates were zeroed in the previous step.

Vtube-laser v2.2-copy to master from measured redraw.png

STEP 10: Optional Alignment Test

This is a cross-check to be sure the process was performed properly. Enter the Inspection Results menu, and press Recalculate for the alignment.

Since VTube is aligning a part to itself, the deviations should be exactly zero.

Vtube-laser v2.2-recalculate alignment perfect match 180.png

STEP 11: Save the VTube Project

Press the Project Save button in the Toolbar, choose the project save path and filename, and save the VTube Project file.