Difference between revisions of "How to Reverse Engineer with Split Bend"
(→STEP 5: Measure The Part) |
(→STEP 5: Measure The Part) |
||
Line 111: | Line 111: | ||
Now scan the center of the inside. Be sure that at least one point in one stripe passes the center inside of the bend. If you are not sure, then release the green button and look at the screen to see if you have points and surfaces that appear to be in the right place. If you know you've scanned the center, then press the RED button to move on to the next straight.<br><br> | Now scan the center of the inside. Be sure that at least one point in one stripe passes the center inside of the bend. If you are not sure, then release the green button and look at the screen to see if you have points and surfaces that appear to be in the right place. If you know you've scanned the center, then press the RED button to move on to the next straight.<br><br> | ||
'''If you want to see a Split Bend measured performed then see video 40 in [[VTube-LASER_Videos]].'''<br><br> | '''If you want to see a Split Bend measured performed then see video 40 in [[VTube-LASER_Videos]].'''<br><br> | ||
− | [[image:vtube-laser_v2.2-splitbendvideo40.png|300px]]<br><br> | + | [[image:vtube-laser_v2.2-splitbendvideo40.png|300px|link=VTube-LASER Videos]]<br><br> |
Press FINISH and APPLY Measure when the measurement is completed. | Press FINISH and APPLY Measure when the measurement is completed. | ||
</td> | </td> |
Revision as of 21:12, 9 February 2016
|
How to Reverse Engineer a Part Using Split Bend
The Split Bend feature allows you to accurately measure bends that equal or exceed 180 degrees. |
STEP 1: Enter PART SETUP Data
Enter the Part Setup data for the new part. Especially enter the PART NUMBER and DEFAULT RADIUS. (You can measure the radius if necessary in Measure Process.) |
STEP 2: Populate the MASTER TUBE DATA Grid
Since the Split Bend feature creates a grid based on the number of straights in the MASTER data, it is important to set the number of points that you will be measuring in the reversed tube. |
STEP 3: Configure the Split Bend Window
The Split Bend window is on the Bend Setup tab in the MASTER TUBE menu. Click into that window. |
|
In the Split Bend window, set any straight that will be treated as a Split Bend. |
STEP 4: Configure the Measure Setup
Enter the Measure Setup menu LASER tab, and set the Split Bend settings:
|
|
In the SEPARATION tab menu, check the following settings:
|
STEP 5: Measure The Part
This step is identical to regular reverse-engineering measuring. |
STEP 6: Choose Build Measured Tube Data Only
Because the MASTER data row count is greater than zero, the Measurement Complete window will offer to allow you to ALIGN the measured tube. |
|
The new measured tube will appear as a blue tube like this. |
STEP 7: Copy Measured to Master
Copy Measured to Master Data in the Data Handling menu. This will overwrite the MASTER data ZEROS with the MEASURED tube data. |
STEP 8: Optional Reset Origin to Zero
Some customers prefer to translate the new MASTER data so that the first point is at 0,0,0. |
STEP 9: View the New Master Tube
View the new MASTER tube by switching the display of the Master tube on, then redrawing and zooming all. |
STEP 10: Optional Alignment Test
This is a cross-check to be sure the process was performed properly. Enter the Inspection Results menu, and press Recalculate for the alignment. |
STEP 11: Save the VTube Project
Press the Project Save button in the Toolbar, choose the project save path and filename, and save the VTube Project file. |
Other Pages
- Back to VTube-LASER
- See also Calibration-Leapfrog-Move Targets
- Purchase the targets at the store.