Difference between revisions of "VTube-LASER v2.9"
(→25px NEW: REMOVED END SCAN DIAMETER TOLERANCE RESTRICTION) |
(→25px OTHER CHANGES) |
||
(5 intermediate revisions by one user not shown) | |||
Line 149: | Line 149: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]] FIX: VTUBE NOW DRAWS DIAMETER EVEN WITH ZERO-LENGTH STRAIGHTS== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | In previous versions, zero length straights would stop the diameter from drawing.<br><br> | ||
+ | This has been fixed in build 95 of version 2.9. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube_v2.9_zerolength_straight_fix.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
<br><br> | <br><br> | ||
Line 188: | Line 204: | ||
* It can import multiple PRT files into a single assembly. | * It can import multiple PRT files into a single assembly. | ||
* It can batch-convert multiple PRT file into a folder of VTube project files (VTP). | * It can batch-convert multiple PRT file into a folder of VTube project files (VTP). | ||
+ | <br><br> | ||
+ | '''Note: Build 91 makes PRT batch mode conversion much faster.''' | ||
+ | <br><br> | ||
+ | '''Note: Build 95 allows for 180-degree bends in PRT files.''' | ||
+ | <br><br> | ||
</td> | </td> | ||
<td> | <td> | ||
Line 195: | Line 216: | ||
</table> | </table> | ||
<br><br> | <br><br> | ||
− | |||
− | |||
− | |||
==[[image:Check.jpg|25px]] NEW: IMPORT MULTIPLE SUPRAVISION FILES== | ==[[image:Check.jpg|25px]] NEW: IMPORT MULTIPLE SUPRAVISION FILES== | ||
Line 298: | Line 316: | ||
==[[image:Check.jpg|25px]] OTHER CHANGES== | ==[[image:Check.jpg|25px]] OTHER CHANGES== | ||
− | + | ||
− | + | * Build 98: The DCP (Diameter Cut Plane) now saves to project files and the default project file. | |
− | + | * Build 98: We reverted back to the correct scanning sound from the previous version. (This version accidentally included an experimental sound. Customers don't like it!) | |
* The PREVIOUS feature that steps back in the measurement step during measurement had some serious bugs. They are fixed. '''(NOTE: Do not use the "Previous" command in earlier versions.)''' | * The PREVIOUS feature that steps back in the measurement step during measurement had some serious bugs. They are fixed. '''(NOTE: Do not use the "Previous" command in earlier versions.)''' | ||
− | |||
− | |||
− | |||
− | |||
− | |||
<br><br> | <br><br> | ||
Latest revision as of 04:36, 15 November 2017
Revision 2.9Release Date: November 1, 2017
|
MAJOR NEW FEATURE: ASSEMBLY
VTube now allows you to include multiple tubes in a single project.
See video 75 in the VTube-LASER Videos page |
We reverse-engineered this entire assembly in about 30 minutes. |
MAJOR ENHANCEMENT: END SCANNING IS MUCH IMPROVED
The end-scan engine is completely redesigned in version 2.9
This change alone is worth the upgrade.
|
NEW: END POINT DIMENSION FOR OFFSET POINTS DURING MEASUREMENT
VTube now automatically draws a linear dimension in the viewport between the scanned point and the final offset point to confirm that the distance is correct. |
NEW: CUSTOM REPORTABLE MEASURE NOTE FOR EACH MEASURE
VTube-LASER allows you to enter a custom measure note before a measure. This note can then be displayed in reports. |
NEW: THE MEASURE DATE/TIME CAN BE REPORTED
VTube-LASER records and stores the measure date/time - and it can now be included in reports. |
REMOVED END SCAN DIAMETER TOLERANCE RESTRICTION
VTube would refuse measurements that were too far from the end of the actual diameter surface of the tube. This does nothing but frustrate end users. Sometimes it is necessary to scan points that are far from the diameter. |
FIX: VTUBE NOW DRAWS DIAMETER EVEN WITH ZERO-LENGTH STRAIGHTS
In previous versions, zero length straights would stop the diameter from drawing. |
ENHANCED - Bender NUMBER in BENDER SETUP Saved and Recalled with Project File
Customers that have many benders prefer to have the bender number saved in the project file because it is normal to associate the project with a bender.
|
ENHANCED - REMOVED "KEEP CUT PLANE" DIALOG
Customers never choose any other option than to keep the current cut plane, so we removed this dialog to save time. |
NEW: IMPORT VECTOR LASERVISION PRT FILES
VTube-STEP (included in VTube-LASER) can now import Laservision PRT files:
|
NEW: IMPORT MULTIPLE SUPRAVISION FILES
VTube-STEP (included in VTube-LASER) can now import multiple Supravision files.
|
NEW: IMPORT MULTIPLE SOLID EDGE FILES INTO AN ASSEMBLY
Import multiple SOLID EDGE files at one time into an ASSEMBLY.
|
ENHANCED: MORE USER INTERFACE SKINS TO CHOOSE FROM
There are now many more user interface skins to choose from in System Options. |
ENHANCED SOLID MODELING ENGINE
The solid modeling engine was updated. |
NEW: MADE CHANGES FOR FARO USB DRIVER VERSION 6
The version 6 driver for FARO would sometimes not reconnect after having left the scanner control window, so VTube now automatically disconnects and reconnects when you exit that window. |
NEW: "NO WAIT" FEATURE FOR SUPRAVISION NETWORK ALLOWS USB FLASH DRIVE COMMUNICATIONS
The new SV No Wait feature allows you to communicate with benders using the Supravision Network protocol with USB flash drives. When VTube-LASER performs a RECALL, it no longer waits for an immediate answer. This means that it will never time-out in this mode. It assumes that the answer will come an undetermined future time.
|
OTHER CHANGES
- Build 98: The DCP (Diameter Cut Plane) now saves to project files and the default project file.
- Build 98: We reverted back to the correct scanning sound from the previous version. (This version accidentally included an experimental sound. Customers don't like it!)
- The PREVIOUS feature that steps back in the measurement step during measurement had some serious bugs. They are fixed. (NOTE: Do not use the "Previous" command in earlier versions.)
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature