Difference between revisions of "VTube-LASER v2.9.5"
(→25pxNEW - DENGLER VDS EXPORT(XYZ Data)) |
(→25pxNEW - DENGLER VDS EXPORT(XYZ Data)) |
||
Line 188: | Line 188: | ||
<td> | <td> | ||
[[image:vts_2.9.5_dengler_vds_export.png|600px]] | [[image:vts_2.9.5_dengler_vds_export.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - MINIMUM CLAMP LENGTH== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=400> | ||
+ | VTube has a new Minimum Clamp Length field in the Part Setup menu.<br><br> | ||
+ | If any bender data length is shorter than the minimum clamp length, then VTube will now issue a warning in the header above the viewport. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:vts_2.9.5_minimum_clamp_length.png|600px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - ZERO-DEGREE BEND ANGLE WARNING== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=400> | ||
+ | If any bend angle is less than 0.1 degrees, then VTube will now issue a warning in the header above the viewport. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:vts_2.9.5_zero-degree_bend.png|600px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> |
Revision as of 00:15, 3 March 2018
Revision 2.9.5Release Date: Not Released
|
ENHANCED - FASTER USER INTERFACE
VTube is now faster due to some important changes to the user interface. |
FIX - SOLID MODEL IMAGE PRINT IN REPORTS
VTube is designed to handle multiple displays. |
NEW - SEPARATE PERSPECTIVE MODES FOR STEP and LASER WINDOWS
In previous versions, there was only a single Perspective Mode switch. |
NEW - REQUEST REVERSE CALC WHEN EXITING THE LRA GRIDS
When you edit the data in the LRA grid, VTube-LASER now assumes that you probably mean to perform a reverse calc. |
FIX - REPAIRED LOSS OF ORIGINAL ORIENTATION DURING REVERSE CALC
VTube always attempts to keep the original XYZ orientation when you perform a Reverse Calc from LRA to centerline XYZ data. |
FIX - BUILD TO TUBE TO SOLIDWORKS
VTube would incorrectly build a single tube to both a single part drawing and a SOLIDWORKS assembly. |
NEW - BEND-TECH 7X IMPORT
BEND-TECH changed the data file format when introducing version 7. Now VTube can import the new 7x format as well as the older version 6 format. |
NEW - DENGLER VDS IMPORT (XYZ Data)
VTube can now import DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.) |
NEW - DENGLER VDS EXPORT(XYZ Data)
VTube can now export DENGLER VDS files. (DENGLER VDS files contain centerline XYZ coordinates.) |
NEW - MINIMUM CLAMP LENGTH
VTube has a new Minimum Clamp Length field in the Part Setup menu. |
NEW - ZERO-DEGREE BEND ANGLE WARNING
If any bend angle is less than 0.1 degrees, then VTube will now issue a warning in the header above the viewport. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature