Difference between revisions of "VTube-LASER v2.9.14"
(→25pxNEW - REPORT ABSOLUTE CONRAC CORRECTIONS) |
(→25px NEW - RONIKolli7 Bender Simulator ASCII XYZ File Import) |
||
(14 intermediate revisions by one user not shown) | |||
Line 6: | Line 6: | ||
==Revision 2.9.14== | ==Revision 2.9.14== | ||
− | Release Date: | + | Release Date: August 28, 2018<br> |
− | Current Build: | + | Current Build: 3 |
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
Line 23: | Line 23: | ||
__TOC__ | __TOC__ | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - VTUBE IS NOW COMPATIBLE WITH THE NEW FARO 8-AXIS USB DRIVER (6.2.0.26) == | ||
+ | |||
+ | <table cellpadding=10 width=1200> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | [[image:usbicon_black.png|100px]]<br> | ||
+ | Previous versions of VTube-LASER will not read the ball probe values with this new FARO USB driver.<br><br>Version 2.9.14 was changed to work with this new FARO driver. In fact, this FARO driver is highly recommended as long as you have this version of VTube-LASER or newer.<br><br> | ||
+ | You can download this latest FARO driver from this [https://www.advancedtubularsupport.com/faro-arm-drivers.html support page.] | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:faro-quantum-m-scanner.png|400px]] | ||
+ | </td> | ||
+ | |||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
==[[image:Check.jpg|25px]]NEW - ENTER FRACTION VALUES for FLOATING POINT in PART SETUP, XYZ GRIDS, and LRA GRIDS == | ==[[image:Check.jpg|25px]]NEW - ENTER FRACTION VALUES for FLOATING POINT in PART SETUP, XYZ GRIDS, and LRA GRIDS == | ||
Line 66: | Line 88: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]FIXED - CLEARING ALL CUT PLANES from the CUT PLANE LIST NOW WORKS == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 72: | Line 94: | ||
<td width=300> | <td width=300> | ||
− | + | We discovered that, when you delete the entire list of Cut Planes, VTube-LASER will most likely bring at least one of them back. (They are not cleared permanently.)<br><br> | |
− | + | This has been fixed so that cleared Cut Planes never reappear. | |
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:multiplecutplanes.png|500px]] |
</td> | </td> | ||
Line 87: | Line 108: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]] NEW - REPORT ABSOLUTE CONRAC CORRECTIONS == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 93: | Line 114: | ||
<td width=300> | <td width=300> | ||
− | + | VTube-LASER can now report absolute CONRAC bender corrections using new HTML report template values.<br><br> | |
− | + | [[image:conracbender.png|300px]]<br><br> | |
+ | The two new tokens to use inside the html tags are: | ||
+ | <br> | ||
+ | * <vtube_val>Array_Lcor_Absolute</vtube_val> | ||
+ | *<vtube_val>Array_Rcor_Absolute</vtube_val> | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtl_2.9.14_conrac_correction_report.png|500px]] |
+ | |||
</td> | </td> | ||
Line 107: | Line 133: | ||
<br><br> | <br><br> | ||
− | + | ==[[image:Check.jpg|25px]] NEW - RONIKolli7 Bender Simulator ASCII XYZ File Import == | |
− | ==[[image:Check.jpg|25px]]NEW - | + | |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 114: | Line 139: | ||
<td width=300> | <td width=300> | ||
− | VTube- | + | [[image:3slogo.png|150px]]<br><br> |
− | + | VTube-STEP mode can now import RONIKolli7 bender simulator ASCII XYZ files.<br><br> | |
+ | That data imported includes: | ||
+ | <br> | ||
+ | * Part Number (filename) | ||
+ | * Material Note | ||
+ | * Diameter | ||
+ | * Wall Thickness | ||
+ | * XYZ + centerline Radius | ||
+ | |||
+ | <br><br> | ||
+ | VTube also calculates the default radius and the Cut Length during the import. | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image:vtl_2.9. | + | [[image:vtl_2.9.14_ronikolli7_ascii_xyz.png|600px]] |
</td> | </td> | ||
Line 135: | Line 170: | ||
<td width=900> | <td width=900> | ||
+ | |||
+ | * Probe point throughput is potentially 2.5 faster than in previous versions. | ||
</td> | </td> |
Latest revision as of 21:41, 29 August 2018
Revision 2.9.14Release Date: August 28, 2018
|
NEW - VTUBE IS NOW COMPATIBLE WITH THE NEW FARO 8-AXIS USB DRIVER (6.2.0.26)
|
NEW - ENTER FRACTION VALUES for FLOATING POINT in PART SETUP, XYZ GRIDS, and LRA GRIDS
We discovered a customer that had to manually convert Imperial fractional units from a tube print. So we taught VTube how to accept fraction values in the PART SETUP, XYZ GRIDS, and LRA GRIDS. Acceptable Fraction Forms
Rule Breaker Examples
|
FIXED - CLEARING ALL CUT PLANES from the CUT PLANE LIST NOW WORKS
We discovered that, when you delete the entire list of Cut Planes, VTube-LASER will most likely bring at least one of them back. (They are not cleared permanently.) |
NEW - REPORT ABSOLUTE CONRAC CORRECTIONS
NEW - RONIKolli7 Bender Simulator ASCII XYZ File Import
OTHER CHANGES
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature