Difference between revisions of "VTube-LASER v2.9.15"
(→25pxFIX - IMPORTANT UPDATE for IMPORTING and MEASURING 180-DEGREE BENDS) |
(→25px OTHER CHANGES) |
||
(8 intermediate revisions by one user not shown) | |||
Line 68: | Line 68: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]NEW - SUPRAVISION BATCH IMPORT - NOW USES YOUR DEFAULT SETUP TO BUILD PROJECT FILES == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 74: | Line 74: | ||
<td width=300> | <td width=300> | ||
− | + | The Supravision batch import can import any number of Supravision files at one time - building huge numbers of VTube project files in minutes.<br><br> | |
− | + | We added the ability for this batch engine to automatically use your current project default when importing the data. | |
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vts_v2.9.15_batch_sv_import.png|600px]] |
</td> | </td> | ||
Line 88: | Line 88: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] NEW - | + | ==[[image:Check.jpg|25px]] NEW - VTUBE-STEP NOW IMPORTS AUTODESK INVENTOR TUBE XYZ FILES == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 94: | Line 94: | ||
<td width=300> | <td width=300> | ||
− | + | Autodesk Inventor can create text files that contain the centerline XYZ data for a tube.<br><br> | |
− | + | VTube-STEP can now import these files. | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vts_2.9.15_autodesk_inventor_import.png|600px]] |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
Line 151: | Line 116: | ||
<td width=900> | <td width=900> | ||
− | * | + | *Fix - "Reset Point Labels" - The point labels no longer revert to the previous state if you save the project after a point label reset. |
+ | |||
+ | |||
</td> | </td> |
Latest revision as of 06:07, 9 October 2018
Revision 2.9.15Release Date: October 8, 2018
|
NEW - END LENGTH FILTER - SHIFTS LENGTH CORRECTIONS BETWEEN A-END and B-END
FIX - IMPORTANT UPDATE for IMPORTING and MEASURING 180-DEGREE BENDS
If you import models with 180-degree bends, then you will use the Split Bend COLLECTION feature in VTube-STEP. |
NEW - SUPRAVISION BATCH IMPORT - NOW USES YOUR DEFAULT SETUP TO BUILD PROJECT FILES
The Supravision batch import can import any number of Supravision files at one time - building huge numbers of VTube project files in minutes. |
NEW - VTUBE-STEP NOW IMPORTS AUTODESK INVENTOR TUBE XYZ FILES
Autodesk Inventor can create text files that contain the centerline XYZ data for a tube. |
OTHER CHANGES
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature