Difference between revisions of "VTube-LASER v2.9.17"
From ATTWiki
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 2.9.17== Release Date: Unreleased<br> Current Build: 2 * Back to VTube-LAS...") |
(→25pxNEW - Reverse XYZ Data and Reset Point Labels at the same time) |
||
Line 30: | Line 30: | ||
<td width=300> | <td width=300> | ||
− | VTube-LASER | + | VTube-LASER now handles point clouds in storage we call "buckets." With this feature:<br><br> |
+ | |||
+ | * Scan point clouds into list of point cloud buckets using the LASER scanner. | ||
+ | * Turn buckets of points on our off. | ||
+ | * Select points on the screen then press DELETE to delete them from the buckets. | ||
+ | * Measure the distance between any two points. | ||
+ | * Transfer the point clouds into SOLIDWORKS. | ||
+ | * Transfer the point clouds into an ASCII file for use in any other program. | ||
+ | * Point clouds are stored and recalled to/from the VTube-LASER project file. | ||
+ | * Point cloud changes are stored in the UNDO memory. If you delete the wrong set of points - just press UNDO. | ||
+ | * Set the color of each bucket of point clouds. | ||
+ | </td> | ||
<td> | <td> | ||
− | [[image:vtl_v2.9. | + | [[image:vtl_v2.9.17_PointCloudDimension.png|800px]] |
</td> | </td> | ||
Revision as of 21:31, 16 November 2018
Revision 2.9.17Release Date: Unreleased
|
Contents |
NEW - Reverse XYZ Data and Reset Point Labels at the same time
VTube-LASER now handles point clouds in storage we call "buckets." With this feature:
|
Fix - Synchronize Reversed XYZ Data in STEP and LASER
When you have STEP and LASER open at the same time on multiple screens, it is possible to reverse either screen's XYZ coordinates. This fix updates both screens correctly when you reverse the coordinates in either screen. |
New - Import the EL Premier TOOL setup to VTube-LASER Bender Setup
Using the current tool setup at the EL Premier is very helpful - so that you don't have to re-enter the values after a first-time send to the bender. So now you can recall just the tool setup from the Premier in order to keep the current tool setup. |
Fix - Eaton Leonard Data Transfer to Additional Setup Window
We fixed a bug that prevented data that was recalled from the bender from being transferred to the Additional Data menu. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature