− | + | The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to the 180-degree bend.<br><br>Also, the wrong number of rows was sent to Bender Setup. For a single 180-degree bend part, there should only be two correction rows. VTube was sending three rows of data for two 90-degree bends.<br><br> | |
This is because VTube-LASER was not compressing the data properly when Split Bend measure was on. <br><br> | This is because VTube-LASER was not compressing the data properly when Split Bend measure was on. <br><br> | ||
This has been fixed in this version. | This has been fixed in this version. |
Revision as of 04:00, 28 November 2018
Revision 2.9.17Release Date: Unreleased
|
Contents |
NEW - Scan and Measure Point Clouds
VTube-LASER now handles point clouds in storage we call "buckets." This allows you to scan anything into VTube-LASER - not just tubes. With this feature:
|
NEW - Automatic Reset Straight Count at Measure
If VTube-LASER starts a measure setup with ZERO straights, then it automatically resets to the MASTER straight count. |
NEW - MAX Points for Cylinder Stripes Is Now 50
Through some experimentation, any point count above 50 per stripe is not helpful in VTube-LASER. For example, as you approach 1000 points per stripe, it slows the math engine significantly and actually causes more Cylinder Fit problems than it solves. |
FIX - Split Bend Corrections in Bend Setup (Important fix for 180-degree bend correction)
The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to the 180-degree bend. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature