Difference between revisions of "VTube-LASER-Compatible HEXAGON Scanners and Arms"

From ATTWiki
Jump to: navigation, search
(HEXAGON Arms)
(HEXAGON Scanner Support)
 
(25 intermediate revisions by one user not shown)
Line 9: Line 9:
 
</td>
 
</td>
 
<td width=700>
 
<td width=700>
[[image:HEXAGON_RS6_Scanner.png|300px]]<br><br>
+
[[image:HEXAGON_AS1_Scanner.png|300px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 17: Line 17:
 
See also [[VTube-LASER ROMER RDS Performance Recommendations]]
 
See also [[VTube-LASER ROMER RDS Performance Recommendations]]
  
__NOTOC__
+
__TOC__
 
+
==HEXAGON Scanner Driver Versions Supported==
+
+
<table width= 600>
+
<tr cellpadding=10>
+
<td width=200>
+
“RS” refers to “ROMER Scanner”<br><br>
+
# The RS1 scanner requires RDS 4.0 or 4.1 – but not newer.
+
# RDS 4.2.0 or newer should be used for scanner versions RS2, RS3, RS4, and RS5
+
# RDS 4.2.1 is tested and works well.
+
# RDS 4.2.2 is tested and works well.
+
# RDS 4.2.3 is tested and works well.
+
# RDS 5.0.0 is tested and works well. This version is required for 8-series of the HEXAGON Absolute Arms.
+
# RDS 5.2.0 is tested and works well.
+
# RDS 5.3.0 is tested and works well.  [https://www.advancedtubularsupport.com/hexagon-absolute-arm-drivers.html Download from our support site]
+
</td>
+
</tr>
+
</table>
+
 
+
<br><br><br>
+
  
 
==HEXAGON Arms==
 
==HEXAGON Arms==
Line 46: Line 26:
 
!  
 
!  
 
|-
 
|-
| ROMER Arm Version 7 Series<br>7-axis laser scanner
+
| style="width: 300pt;" | ROMER Arm Version 7 Series<br>7-axis laser scanner
 
| [[image:ROMER7.png|400px]]
 
| [[image:ROMER7.png|400px]]
 
|  
 
|  
Line 55: Line 35:
 
|-
 
|-
 
| ROMER Arm Version 7 Series<br>6-axis ball probe
 
| ROMER Arm Version 7 Series<br>6-axis ball probe
| [[image:ROMER7-SixAxis.png|400px]]
+
| [[image:ROMER7-SixAxis.jpg|400px]]
 +
|
 +
|-
 +
| HEXAGON Arm Version RA8 Series<br>6-axis ball probe
 +
| [[image:RA8-SixAxis.png|400px]]
 
|  
 
|  
 
|}
 
|}
<br><br>
 
 
==HEXAGON Scanners Website==
 
 
[https://www.hexagonmi.com/en-US/products/3d-laser-scanners Romer Scanners Site]
 
 
<br><br>
 
<br><br>
  
 
==HEXAGON Scanner Support==
 
==HEXAGON Scanner Support==
  
According to HEXAGON, VTube-LASER can support any scanner supported by RDS directly, including...<br><br>
+
VTube-LASER can support any scanner supported by RDS directly, including...<br><br>
 
   
 
   
<table width= 800>
 
<tr cellpadding=10>
 
<td width=300>
 
This scanner is for the RA8 7-axis arms only.  It is very good for parts that are highly reflective or change reflectivity on different parts of the surface.  The SHINE technology takes three different exposures of each laser stripe in order to properly take in data from surfaces that have different reflectivity along the stripe.
 
</td>
 
<td>
 
[[image:HEXAGON_RS6_Scanner.png|300px]]<br><br>
 
</td>
 
</tr>
 
  
<tr cellpadding=10>
+
{| class="wikitable"
<td width=300>
+
! Scanner Description
This is for RA8 7-axis Portable Arms.  It is best for parts that have consistent surface reflectivity properties along the entire part because the camera chooses a single exposure for each stripe.   
+
! Image
</td>
+
|-
<td>
+
| style="width: 300pt;" | The AS1 scanner is for the RA8 7-axis arms.  It is the upgraded version of the RS6. It is very good for parts that are highly reflective or change reflectivity on different parts of the surface.  The SHINE technology takes three different exposures of each laser stripe in order to properly take in data from surfaces that have different reflectivity along the stripe.
[[image:HEXAGON_RS5_Scanner.png|300px]]
+
| [[image:HEXAGON_AS1_Scanner.png|400px]]
</td>
+
|-
</tr>
+
| The RS6 scanner is for the RA8 7-axis arms.  It is very good for parts that are highly reflective or change reflectivity on different parts of the surface.  The SHINE technology takes three different exposures of each laser stripe in order to properly take in data from surfaces that have different reflectivity along the stripe.
 
+
|[[image:HEXAGON_RS6_Scanner.png|400px]]
 
+
|-
<tr cellpadding=10>
+
| This is for RA8 7-axis Portable Arms.  It is best for parts that have consistent surface reflectivity properties along the entire part because the camera chooses a single exposure for each stripe.   
<td width=300>
+
| [[image:HEXAGON_RS5_Scanner.png|400px]]
 
+
|-
* RA7 7-axis Portable Arms
+
| RA7 7-axis Portable Arm Scanners
</td>
+
| [[image:ROMER_Scanner_Plus_Hex_Logo.png|400px]]
<td>
+
|-
[[image:ROMER_Scanner_Plus_Hex_Logo.png|300px]]
+
| CMS108 Scanners
</td>
+
|[[image:ROMER_CMSScanner.png|400px]]
 
+
|-
</tr>
+
| HP-L-20.8<br><br>
 
+
|[[image:HP-L-20.8.png|400px]]
<table width= 800>
+
|-
<tr cellpadding=10>
+
| HP-L-8.9 scanners<br><br>This scanner is for attachment of a scanner on the same 6-axis arms that used Tube Shaper software (Tube Shaper is retired). See the [https://www.hexagonmi.com/en-US/products/3d-laser-scanners/hpl89-laser-scanner ROMER HP-L-8.9 website for video of how this scanner works on a 6-axis arm.]<br><br>
<td width=300>
+
Note: The articulation of a 6-axis arm with this laser is not as good as that of a 7-axis arm.  (This laser scanner is not used on a 7-axis arm.)  With a 6-axis arm, the user is forced to approach the tube from restricted directions. Watch the video on the HEXAGON site to see how this scanner works on a 6-axis arm.
* CMS108 Scanners
+
|[[image:ROMER_HPLScanner.png|400px]]
</td>
+
|-
<td>
+
|* Leica Absolute Scanner for Long Distances
[[image:ROMER_CMSScanner.png|300px]]
+
</td>
+
</tr>
+
 
+
 
+
<table width= 800>
+
<tr cellpadding=10>
+
<td width=300>
+
* HP-L-20.8<br><br>
+
* RA7 and RA8 Portable Arms with HP-L-8.9 scanners<br><br>This scanner is for attachment of a scanner on the same arms that use Tube Shaper software. See the [https://www.hexagonmi.com/en-US/products/3d-laser-scanners/hpl89-laser-scanner ROMER HP-L-8.9 website]<br><br>
+
* For use on 6 axis arms.
+
</td>
+
<td>
+
[[image:ROMER_HPLScanner.png|300px]]
+
</td>
+
 
+
</tr>
+
 
+
<tr cellpadding=10>
+
<td width=200>
+
* Leica Absolute Scanner for Long Distances
+
 
* The LR model can measure a 10 meter volume.
 
* The LR model can measure a 10 meter volume.
 
* The MR model can measure a 20 meter volume.
 
* The MR model can measure a 20 meter volume.
 
* [https://www.youtube.com/watch?v=TQ3Vc9nTfjs YouTube video of LAS]
 
* [https://www.youtube.com/watch?v=TQ3Vc9nTfjs YouTube video of LAS]
</td>
+
|[[image:LeicaLAS.png|400px]]
<td>
+
|}
[[image:LeicaLAS.png|300px]]
+
</td>
+
</tr>
+
 
+
 
+
</table>
+
<br><br>
+
  
==ROMER Ball Probe Support==
+
==HEXAGON Arm Ball Probe Support==
 
   
 
   
 
<table width= 600>
 
<table width= 600>
Line 148: Line 90:
 
</td>
 
</td>
 
</tr>
 
</tr>
</table>
 
<br><br>
 
 
 
==ROMER Versions==
 
 
<table width= 600>
 
<tr cellpadding=10>
 
<td width=200>
 
RDS 4.2.1 and 4.2.2 work well.  v4.2.2 has anti-outlier (anti-flyer) algorithms for highly reflective surfaces.<br><br>
 
We do not recommend RDS 4.2.3 because it has an issue that causes it to unload regularly, and it is very sluggish compared to the earlier versions.
 
</td>
 
</tr>
 
</table>
 
<br><br>
 
 
==How to Determine Your Current RDS Version==
 
 
<table width= 600>
 
<tr cellpadding=10>
 
<td width=200>
 
Left click on the System Tray icon.
 
</td>
 
<td>
 
[[image:Left click system tray icon.png|300px]]
 
</td>
 
</tr>
 
 
<tr cellpadding=10>
 
<td width=200>
 
Right click on the measuring center icon.
 
</td>
 
<td>
 
[[image:Right click on the measuring center icon.png|300px]]
 
</td>
 
</tr>
 
 
<tr cellpadding=10>
 
<td width=200>
 
Left click on About.
 
</td>
 
<td>
 
[[image:RDS left click on about.png|300px]]
 
</td>
 
</tr>
 
 
<tr cellpadding=10>
 
<td width=200>
 
The RDS About window will display.
 
</td>
 
<td>
 
[[image:RDS4.3.2_About_Dialog.png|300px]]
 
</td>
 
</tr>
 
 
 
 
 
 
</table>
 
</table>
 
<br><br>
 
<br><br>

Latest revision as of 14:18, 9 September 2022

HEXAGON Arms and Scanners that Are Compatible with VTube-LASER



HEXAGON AS1 Scanner.png


See also VTube-LASER ROMER RDS Performance Recommendations

Contents


HEXAGON Arms

Arm Type Image
ROMER Arm Version 7 Series
7-axis laser scanner
ROMER7.png
HEXAGON Arm Version RA8 Series
7-axis laser scanner
RA8.png
ROMER Arm Version 7 Series
6-axis ball probe
ROMER7-SixAxis.jpg
HEXAGON Arm Version RA8 Series
6-axis ball probe
RA8-SixAxis.png



HEXAGON Scanner Support

VTube-LASER can support any scanner supported by RDS directly, including...


Scanner Description Image
The AS1 scanner is for the RA8 7-axis arms. It is the upgraded version of the RS6. It is very good for parts that are highly reflective or change reflectivity on different parts of the surface. The SHINE technology takes three different exposures of each laser stripe in order to properly take in data from surfaces that have different reflectivity along the stripe. HEXAGON AS1 Scanner.png
The RS6 scanner is for the RA8 7-axis arms. It is very good for parts that are highly reflective or change reflectivity on different parts of the surface. The SHINE technology takes three different exposures of each laser stripe in order to properly take in data from surfaces that have different reflectivity along the stripe. HEXAGON RS6 Scanner.png
This is for RA8 7-axis Portable Arms. It is best for parts that have consistent surface reflectivity properties along the entire part because the camera chooses a single exposure for each stripe. HEXAGON RS5 Scanner.png
RA7 7-axis Portable Arm Scanners ROMER Scanner Plus Hex Logo.png
CMS108 Scanners ROMER CMSScanner.png
HP-L-20.8

HP-L-20.8.png
HP-L-8.9 scanners

This scanner is for attachment of a scanner on the same 6-axis arms that used Tube Shaper software (Tube Shaper is retired). See the ROMER HP-L-8.9 website for video of how this scanner works on a 6-axis arm.

Note: The articulation of a 6-axis arm with this laser is not as good as that of a 7-axis arm. (This laser scanner is not used on a 7-axis arm.) With a 6-axis arm, the user is forced to approach the tube from restricted directions. Watch the video on the HEXAGON site to see how this scanner works on a 6-axis arm.

ROMER HPLScanner.png
* Leica Absolute Scanner for Long Distances
  • The LR model can measure a 10 meter volume.
  • The MR model can measure a 20 meter volume.
  • YouTube video of LAS
LeicaLAS.png

HEXAGON Arm Ball Probe Support

All ball probe systems on devices that run through RDS are compatible with VTube-LASER.



Other Pages