Difference between revisions of "HEXAGON Absolute Arm Feature Packs or Control Packs"
(→2021 (Newer) CP-Series Arm Control Pack) |
(→OLDER ARMS: Three Cables Per ROMER Arm) |
||
(17 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | + | <table width=1000> | |
− | <table width= | + | <tr> |
− | <tr | + | <td width=300> |
− | <td width= | + | __TOC__ |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
− | <td width= | + | <td width=20> |
− | [[image: | + | </td> |
+ | <td> | ||
+ | [[image:HEXAGONRDS_with_AS1_Scanner.png|500px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | * Back to [[VTube-LASER]] | ||
+ | * See also [[RDS Versions for ROMER Scanners]] | ||
+ | * See also [[VTube-LASER ROMER RDS Performance Recommendations]] | ||
− | |||
− | |||
− | = | + | =Control Pack Cabling Between Arms and Computers= |
− | ==NEWER ARMS: Two Cables Per | + | ==NEWER ARMS: Two Cables Per Arm== |
<table width= 1000 > | <table width= 1000 > | ||
Line 41: | Line 40: | ||
</table> | </table> | ||
− | ==OLDER ARMS: Three Cables Per | + | ==OLDER ARMS: Three Cables Per Arm== |
<table width= 1000 > | <table width= 1000 > | ||
Line 61: | Line 60: | ||
</table> | </table> | ||
− | = | + | =About Feature Packs (older arms) or Control Packs (newer arms)= |
<table width= 1000 > | <table width= 1000 > | ||
Line 111: | Line 110: | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ==Older Feature Packs Require that the IP Address Be Manually Fixed in the VTube-LASER Computer== | ||
+ | |||
+ | <table width= 1000 > | ||
+ | <tr cellpadding=10> | ||
+ | <td width=300 valign=top> | ||
+ | The newer HEXAGON Absolute Arm control packs can automatically serve an IP address to the computer using DHCP.<br><br> | ||
+ | With RDS version 4, we experienced some cases where the DHCP service from RDS to the arm stops all internet browsing through other NIC ports. The way to overcome this is to discover what IP address the ROMER arm prefers for the computer, then FIX the IP to that address.<br><br> | ||
+ | On our test computers the ROMER-preferred address is 19.168.178.11.<br><br> | ||
+ | RDS versions 5 and 6 do not need the IP v4 address to be set. Leave it blank in the Network adapter setup. | ||
+ | <br><br> | ||
+ | For customers with active Software Maintenance Plans, if you need help with this, then please contact us and we will be happy to help you set this up. | ||
+ | </td> | ||
+ | <td> | ||
+ | |||
+ | [[image:RDS Computer IP Address.png|700px]]<br><br> | ||
+ | </td> | ||
+ | |||
+ | </tr> | ||
</table> | </table> | ||
<br><br> | <br><br> | ||
Line 119: | Line 141: | ||
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
− | * See | + | * See also [[RDS Versions for ROMER Scanners]] |
+ | * See also [[VTube-LASER ROMER RDS Performance Recommendations]] |
Latest revision as of 18:40, 3 October 2022
|
- Back to VTube-LASER
- See also RDS Versions for ROMER Scanners
- See also VTube-LASER ROMER RDS Performance Recommendations
Control Pack Cabling Between Arms and Computers
NEWER ARMS: Two Cables Per Arm
The newer ROMER scanners communicate with the computer using:
You will need one open Ethernet port and one open USB port for the ROMER arm connection. |
OLDER ARMS: Three Cables Per Arm
The older ROMER scanners communicate using:
You will need one open Ethernet port and one open USB port for the ROMER arm connection. |
About Feature Packs (older arms) or Control Packs (newer arms)
7-Series Arm Feature PackThis is the ROMER Scanning Pack that is attached to the back base of the 7-series arms. It includes ports for power, USB, and Ethernet. |
|
Original 8-Series Arm Control PackThis is the HEXAGON Absolute Arm Control Pack that is attached to the back base of the 8-series arms when the 8-series was originally released. It includes ports for power, USB, and Ethernet. |
|
2021 (Newer) CP-Series Arm Control PackThis is the HEXAGON Absolute Arm Control Pack that is attached to the back base of the newer 8-series arms. This pack is highly recommended for its simplicity compared to older packs. |
Older Feature Packs Require that the IP Address Be Manually Fixed in the VTube-LASER Computer
The newer HEXAGON Absolute Arm control packs can automatically serve an IP address to the computer using DHCP. |
Other Pages
- Back to VTube-LASER
- See also RDS Versions for ROMER Scanners
- See also VTube-LASER ROMER RDS Performance Recommendations