Difference between revisions of "How to Reverse Engineer with Split Bend"
(→STEP 5: Measure The Part) |
(→STEP 4: Configure the Measure Setup) |
||
(39 intermediate revisions by one user not shown) | |||
Line 49: | Line 49: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_set_master_point_count.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
==STEP 3: Configure the Split Bend Window== | ==STEP 3: Configure the Split Bend Window== | ||
Line 62: | Line 61: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_enter_split_bend_window.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 71: | Line 70: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_split_bend_window_straight_selected1.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
==STEP 4: Configure the Measure Setup== | ==STEP 4: Configure the Measure Setup== | ||
Line 82: | Line 79: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | Configure Measure Setup like this:<br><br> | |
− | + | # Press the Measure Setup button in the Navigation pane.<br><br> | |
− | + | # Press the Laser tab if it is not active.<br><br> | |
+ | # Activate the LASER scanner for Split Bends.<br><br> | ||
+ | # Set the number of allowed STRIPES to 50 for Split Bends.<br><br> | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_lasersetup_splitbends.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | Continue with the Measure Setup in the Separation Filter menu<br><br> | |
− | + | # Press the Separation Filter tab.<br><br> | |
− | + | # Set the SPLIT BEND Scan Type to DISTANCE.<br><br> | |
+ | # Set the SPLIT BEND Scan Distance to 0.015" (or .38 mm). <br><br> | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_separationsetup_splitbend.png.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 112: | Line 112: | ||
'''If you want to see a Split Bend measurement then see video 40 in [[VTube-LASER_Videos]].'''<br><br> | '''If you want to see a Split Bend measurement then see video 40 in [[VTube-LASER_Videos]].'''<br><br> | ||
[[image:vtube-laser_v2.2-splitbendvideo40.png|400px|link=VTube-LASER Videos]]<br><br> | [[image:vtube-laser_v2.2-splitbendvideo40.png|400px|link=VTube-LASER Videos]]<br><br> | ||
− | Press FINISH and | + | Press FINISH and Build Measured Tube when the measurement is completed. |
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube-laser- | + | [[image:vtube-laser-v4_measureguide_cylindricaltube.png|200px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 126: | Line 126: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | FINISH and Build Measured Tube and press okay when the next popup screen appears. This is asking users to verify they want to make the tube they just measured the new MASTER tube going forward. <br><br> | |
− | + | ||
− | + | ||
− | + | [[image:vtube-laser_v4_copy.png|300px]]<br> | |
− | + | ||
− | [[image:vtube- | + | <table cellpadding=10 width="900"> |
− | + | ||
− | < | + | |
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | |||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_master.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 152: | Line 149: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_copy_measured_to_master1.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 164: | Line 161: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_reset_origin_to_zero.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 202: | Line 199: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4-SaveProjects.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 19:58, 16 December 2022
|
How to Reverse Engineer a Part Using Split Bend
The Split Bend feature allows you to accurately measure bends that equal or exceed 180 degrees. |
STEP 1: Enter PART SETUP Data
Enter the Part Setup data for the new part. Especially enter the PART NUMBER and DEFAULT RADIUS. (You can measure the radius if necessary in Measure Process.) |
STEP 2: Populate the MASTER TUBE DATA Grid
Since the Split Bend feature creates a grid based on the number of straights in the MASTER data, it is important to set the number of points that you will be measuring in the reversed tube. |
STEP 3: Configure the Split Bend Window
The Split Bend window is on the Bend Setup tab in the MASTER TUBE menu. Click into that window. |
|
In the Split Bend window, set any straight that will be treated as a Split Bend. |
STEP 4: Configure the Measure Setup
Configure Measure Setup like this:
|
|
Continue with the Measure Setup in the Separation Filter menu
|
STEP 5: Measure The Part
This step is identical to regular reverse-engineering measuring. |
STEP 6: Choose Build Measured Tube Data Only
FINISH and Build Measured Tube and press okay when the next popup screen appears. This is asking users to verify they want to make the tube they just measured the new MASTER tube going forward. STEP 7: Copy Measured to Master
STEP 8: Optional Reset Origin to Zero
STEP 9: View the New Master Tube
STEP 10: Optional Alignment Test
STEP 11: Save the VTube Project
Other Pages
|