Difference between revisions of "How to Reverse Engineer with Split Bend"
(→STEP 4: Measure The Part) |
(→STEP 4: Configure the Measure Setup) |
||
(55 intermediate revisions by one user not shown) | |||
Line 49: | Line 49: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_set_master_point_count.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
==STEP 3: Configure the Split Bend Window== | ==STEP 3: Configure the Split Bend Window== | ||
Line 62: | Line 61: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_enter_split_bend_window.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 71: | Line 70: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_split_bend_window_straight_selected1.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
− | |||
==STEP 4: Configure the Measure Setup== | ==STEP 4: Configure the Measure Setup== | ||
Line 82: | Line 79: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | Configure Measure Setup like this:<br><br> | |
− | + | # Press the Measure Setup button in the Navigation pane.<br><br> | |
− | + | # Press the Laser tab if it is not active.<br><br> | |
+ | # Activate the LASER scanner for Split Bends.<br><br> | ||
+ | # Set the number of allowed STRIPES to 50 for Split Bends.<br><br> | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_lasersetup_splitbends.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | Continue with the Measure Setup in the Separation Filter menu<br><br> | |
− | + | # Press the Separation Filter tab.<br><br> | |
− | + | # Set the SPLIT BEND Scan Type to DISTANCE.<br><br> | |
+ | # Set the SPLIT BEND Scan Distance to 0.015" (or .38 mm). <br><br> | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_separationsetup_splitbend.png.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 107: | Line 107: | ||
<td width=400 > | <td width=400 > | ||
This step is identical to regular reverse-engineering measuring.<br><br> | This step is identical to regular reverse-engineering measuring.<br><br> | ||
− | Press FINISH and | + | When you arrive at the split bend to scan, VTube-LASER will make a special sound and tell you to scan the OUTSIDE of the bend. Scan as much data as you want - up to 250 stripes. The goal is to be sure that at least one point in one of the stripes touches the highest point of the outside of the bend. So you can take as many stripes of data as you want - VTube will take them all in without a problem.<br><br> |
+ | During scanning, release the green button, and look at the screen. You should see a large area of surfaces that pass the point of the outside of the bend. Press the RED button if you are finished scanning the outside and have not come to 250 stripes.<br><br> | ||
+ | Now scan the center of the inside. Be sure that at least one point in one stripe passes the center inside of the bend. If you are not sure, then release the green button and look at the screen to see if you have points and surfaces that appear to be in the right place. If you know you've scanned the center, then press the RED button to move on to the next straight.<br><br> | ||
+ | '''If you want to see a Split Bend measurement then see video 40 in [[VTube-LASER_Videos]].'''<br><br> | ||
+ | [[image:vtube-laser_v2.2-splitbendvideo40.png|400px|link=VTube-LASER Videos]]<br><br> | ||
+ | Press FINISH and Build Measured Tube when the measurement is completed. | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube-laser- | + | [[image:vtube-laser-v4_measureguide_cylindricaltube.png|200px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ==STEP | + | <br><br> |
+ | |||
+ | ==STEP 6: Choose Build Measured Tube Data Only== | ||
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | FINISH and Build Measured Tube and press okay when the next popup screen appears. This is asking users to verify they want to make the tube they just measured the new MASTER tube going forward. <br><br> | |
− | + | ||
− | + | ||
− | + | [[image:vtube-laser_v4_copy.png|300px]]<br> | |
− | + | ||
− | [[image:vtube- | + | <table cellpadding=10 width="900"> |
− | + | ||
− | < | + | |
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | |||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_master.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ==STEP | + | ==STEP 7: Copy Measured to Master== |
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
Line 145: | Line 149: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_copy_measured_to_master1.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ==STEP | + | ==STEP 8: Optional Reset Origin to Zero== |
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
Line 157: | Line 161: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4_reset_origin_to_zero.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | + | ==STEP 9: View the New Master Tube== | |
− | + | ||
− | + | ||
− | ==STEP | + | |
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
Line 178: | Line 179: | ||
</table> | </table> | ||
− | + | ==STEP 10: Optional Alignment Test== | |
− | ==STEP | + | |
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
Line 192: | Line 192: | ||
</table> | </table> | ||
− | ==STEP | + | ==STEP 11: Save the VTube Project== |
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
Line 199: | Line 199: | ||
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube- | + | [[image:vtube-laser_v4-SaveProjects.png|500px]]<br> |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 19:58, 16 December 2022
|
How to Reverse Engineer a Part Using Split Bend
The Split Bend feature allows you to accurately measure bends that equal or exceed 180 degrees. |
STEP 1: Enter PART SETUP Data
Enter the Part Setup data for the new part. Especially enter the PART NUMBER and DEFAULT RADIUS. (You can measure the radius if necessary in Measure Process.) |
STEP 2: Populate the MASTER TUBE DATA Grid
Since the Split Bend feature creates a grid based on the number of straights in the MASTER data, it is important to set the number of points that you will be measuring in the reversed tube. |
STEP 3: Configure the Split Bend Window
The Split Bend window is on the Bend Setup tab in the MASTER TUBE menu. Click into that window. |
|
In the Split Bend window, set any straight that will be treated as a Split Bend. |
STEP 4: Configure the Measure Setup
Configure Measure Setup like this:
|
|
Continue with the Measure Setup in the Separation Filter menu
|
STEP 5: Measure The Part
This step is identical to regular reverse-engineering measuring. |
STEP 6: Choose Build Measured Tube Data Only
FINISH and Build Measured Tube and press okay when the next popup screen appears. This is asking users to verify they want to make the tube they just measured the new MASTER tube going forward. STEP 7: Copy Measured to Master
STEP 8: Optional Reset Origin to Zero
STEP 9: View the New Master Tube
STEP 10: Optional Alignment Test
STEP 11: Save the VTube Project
Other Pages
|