Difference between revisions of "VTube-LASER v2.8.4"
(→25px NEW: MULTISCREEN "SWITCH SCREEN" BUTTONS) |
(→25px BUILD 3 - NEW: GERMAN TRANSLATION UPDATED) |
||
(31 intermediate revisions by one user not shown) | |||
Line 7: | Line 7: | ||
==Revision 2.8.4== | ==Revision 2.8.4== | ||
Original Release Date: June 22, 2017<br> | Original Release Date: June 22, 2017<br> | ||
− | Latest Build: | + | Latest Build: 3 |
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
Line 24: | Line 24: | ||
__TOC__ | __TOC__ | ||
− | + | ==[[image:Check.jpg|25px]] BUILD 1 - NEW: MULTISCREEN "SWITCH SCREEN" BUTTONS== | |
− | ==[[image:Check.jpg|25px]] NEW: MULTISCREEN "SWITCH SCREEN" BUTTONS== | + | |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 40: | Line 39: | ||
</table> | </table> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]] BUILD 2 - IMPROVED: REVERSE CALC== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | In previous versions, | + | In previous versions, when performing REVERSE CALC from bender data to centerline XYZ data, VTube-LASER could not keep the previous part orientation in 3D space when the first leg ran parallel to the Z axis.<br><br> |
− | + | The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.<br><br> | |
+ | The math engine has been improved to handle this condition. | ||
<td> | <td> | ||
− | [[image:vtube- | + | [[image:vtube-laser_2.9.4_reverse calc.png|400px]] |
</td> | </td> | ||
<td> | <td> | ||
Line 54: | Line 54: | ||
</table> | </table> | ||
+ | ==[[image:Check.jpg|25px]] BUILD 2 - NEW: DATUM REPORT TEMPLATES - MEASURED Distances to MASTER DATUM== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Previous versions of VTube could only display DATUM reports with MEASURED-ALIGNED to MEASURED-ALIGNED DATUM or MASTER to MASTER DATUM values.<br><br> | ||
+ | Now VTube-LASER can show DATUM reports with MEASURED-ALIGNED distances to MASTER Datums.<br><br> | ||
+ | <br><br> | ||
+ | To use these new report templates:<br><br> | ||
+ | # Download these two new templates: [https://www.advancedtubular.com/customers/vtube/vtubelaser_v2.8.4_datum_measured2master_report_templates.zip Zip file of Measured to Master Datum Report Templates.] | ||
+ | # Extract them to a folder location that you can find. | ||
+ | # Load VTube-LASER. | ||
+ | # Go to Reports. | ||
+ | # Click on the Templates tab. | ||
+ | # Click on Import. | ||
+ | # Find and click on the new Datum templates. | ||
+ | # Repeat at step 5 for the second template file. | ||
+ | |||
+ | <td> | ||
+ | [[image:vtube-laser_2.8.4_datum_report.png|600px]] | ||
+ | </td> | ||
+ | <td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]] BUILD 2 - IMPROVED: REPORT WINDOW TO FRONT== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | We've improved the REPORT window's ability to come to the top of the current window. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_v2.8.4_report on top.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] BUILD 3 - NEW: GERMAN TRANSLATION UPDATED== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The German translation for VTube-LASER is updated and included in the installation.<br><br> | ||
+ | The translation is in the file '''german_v2.8.4_build3.xls'''. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] BUILD 3 - NEW: JAPANESE TRANSLATION UPDATED== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The Japanese translation for VTube-LASER is updated and included in the installation.<br><br> | ||
+ | The translation is in the file '''japanese_v2.8.4_build3.xls'''. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] BUILD 3 - NEW: FRENCH TRANSLATION UPDATED== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The French translation for VTube-LASER is updated and included in the installation.<br><br> | ||
+ | The translation is in the file '''french_v2.8.4_build3.xls'''. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]] BUILD 3 - FIX: USER INTERFACE ENGLISH GRAMMAR CORRECTIONS== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Our German translator helped us correct several problems with the English in the VTube user interface. | ||
+ | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
=Other Pages= | =Other Pages= |
Latest revision as of 02:31, 10 July 2017
Revision 2.8.4Original Release Date: June 22, 2017
|
BUILD 1 - NEW: MULTISCREEN "SWITCH SCREEN" BUTTONS
When multiple screens are present, then VTube now adds "SWITCH SCREEN" buttons in the toolbars. |
BUILD 2 - IMPROVED: REVERSE CALC
In previous versions, when performing REVERSE CALC from bender data to centerline XYZ data, VTube-LASER could not keep the previous part orientation in 3D space when the first leg ran parallel to the Z axis. |
BUILD 2 - NEW: DATUM REPORT TEMPLATES - MEASURED Distances to MASTER DATUM
Previous versions of VTube could only display DATUM reports with MEASURED-ALIGNED to MEASURED-ALIGNED DATUM or MASTER to MASTER DATUM values.
|
BUILD 2 - IMPROVED: REPORT WINDOW TO FRONT
We've improved the REPORT window's ability to come to the top of the current window.
|
BUILD 3 - NEW: GERMAN TRANSLATION UPDATED
The German translation for VTube-LASER is updated and included in the installation. |
BUILD 3 - NEW: JAPANESE TRANSLATION UPDATED
The Japanese translation for VTube-LASER is updated and included in the installation. |
BUILD 3 - NEW: FRENCH TRANSLATION UPDATED
The French translation for VTube-LASER is updated and included in the installation. |
BUILD 3 - FIX: USER INTERFACE ENGLISH GRAMMAR CORRECTIONS
Our German translator helped us correct several problems with the English in the VTube user interface.
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature