Difference between revisions of "DOCS"

From ATTWiki
Jump to: navigation, search
(Screen Image)
 
(94 intermediate revisions by one user not shown)
Line 1: Line 1:
 
[[image:Docs_screen1.jpg|right]]
 
[[image:Docs_screen1.jpg|right]]
DOCS is a software package that is sold by [[Romer]].  The word "DOCS" means Data Overlay Camera System. Read more about DOCS at these sites:
+
DOCS is a software package that is sold by [[Romer]].  The word "DOCS" means Data Overlay Camera System.
  
 
+
<br>
*At the Hexagon Metrology Web Site: http://www.hexagonmetrology.com.mx/docs?Itemid=34<br>
+
*At the [[Romer]] Web Site: http://us.romer.com/docs-data-overlay-camera-system?Itemid=31<br>
+
*Tube Shop Manager (Version 2.2 and higher): http://us.romer.com/press-releases/docs-2-2-with-tube-shop-manager?Itemid=15
+
 
<br>
 
<br>
 
<br>
 
<br>
 +
 +
==Screen Image==
 +
This is a screen image from DOCS software.<br><br>
 +
[[image:Romer_docs_egrtube.jpg|400px]]
 +
 +
==Solid Model Output==
 +
DOCS can output a solid model that can be imported into [[VTube-STEP]].  However it is our experience that the model is not as precise as models from other solid model programs (like SolidWorks). <br><br>
 +
[[Image:Vtube-step_1_6.jpg|300px]]<br><br>
 +
When calculating centerline data from DOCS solids, you may need to increase the projection tolerance value in the collection grid to make the calculation work.
 +
<br><br>
  
 
==Comparing DOCS to Supravision==
 
==Comparing DOCS to Supravision==
  
  
[[Supravision]] and DOCS are developed by the same company.  [[Supravision]] is a much older program.   
+
[[Supravision]] and DOCS are developed by [[Romer]].  [[Supravision]] is the older legacy program for tube measurementThis matrix offers a comparison between the two software packages:
 +
 
 +
<table cellpadding="15">
  
<table>
 
 
<tr>
 
<tr>
<td width=100>
+
<td width=200 bgcolor="#e3e4f5">
DOCS
+
<font size=5>DOCS Software</font>
 
</td>
 
</td>
<td width=100>
+
<td width=200 bgcolor="#cfe7dc">
Supravision
+
<font size=5>Supravision Software</font>
 
</td>
 
</td>
 
</tr>
 
</tr>
 +
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Active - Continued development
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Static - No more development
 +
</td>
 +
</tr>
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Measures only tube shapes
 +
</td>
 +
</tr>
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Because it is more powerful, it is also more complex.  Thus - this software takes longer to learn.</td>
 +
<td bgcolor="#8ecaae">
 +
Supravision is very easy to learn.
 +
</td>
 +
</tr>
 +
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Can use contact or non-contact measurement
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Can only use non-contact measurement of tube shapes
 +
</td>
 +
</tr>
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Can measure multiple tubes in a single DOCS file
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Can measure one tube per Supravision file
 +
</td>
 +
</tr>
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Romer charges a fee for every bender connected to DOCS.
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
There is no charge from ROMER for connection through Supravision.
 +
</td>
 +
</tr>
 +
 +
<tr>
 +
<td bgcolor="#8085dc">
 +
Tube Shop Manager (TSM) is an optional feature in DOCS.  You must purchase TSM if you want to measure and correct tubes in DOCS software.
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Tube measurement is standard in Supravision (because that is all Supravision can do).
 +
</td>
 +
</tr>
 +
 +
 
</table>
 
</table>
  
*DOCS is undergoing development.  [[Supravision]] development is static.
+
<br><br>
*DOCS allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications. [[Supravision]] can only measuring the tube shape.
+
 
*DOCS can use contact or non-contact measurement[[Supravision]] can only use non-contact measurement of tube shapes.
+
==Our Recommendation==
*DOCS can measure multiple tubes in a single DOCS file.  Supravision measures one tube at a time.
+
As of December, 2007, we have been given a license of DOCS software for evaluation and testing with our [[Benderlink]] software.  This is our recommendation:
 +
<br><br>
 +
#Be prepared for the increased complexity of the program.<br><br>
 +
#If you are a Supravision owner, then we recommend that you view DOCS in action before making a decisionSpecifically ask for a tube demo.  We also recommend that you compare DOCS to our [[VTube-LASER]] software before making a decision.<br><br>
 +
#Also, we recommend that our customers be careful to receive a quotation for '''all''' the options that you will expect with DOCS (like TSM and a sufficient number of bender licenses if you plan to connect to benders through Benderlink).
 +
 
 +
<br><br>
 +
 
 +
==Communication with Supravision Network Protocol==
 +
 
 +
See this link for information on which version of DOCS will communicate using SVNET: [http://www.advancedtubular.wiki/index.php?title=Supravision_Network_Protocol#DOC_Versions_to_Use_for_SVNET]
 +
 
 +
==Principles for Corrections Loops with SVNET and DOCS==
 +
 
 +
 
 +
<table cellpadding="15">
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#8085dc">
 +
</td>
 +
<td width=400 bgcolor="#8085dc">
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#FFFFFF">
 +
<font size=5>Principles</font>
 +
</td>
 +
<td width=400 bgcolor="#cfe7dc">
 +
<font size=5>Reasons</font>
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#8085dc">
 +
</td>
 +
<td width=400 bgcolor="#8085dc">
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td bgcolor="#FFFFFF">
 +
If the data at the bender control has changed and...
 +
<br><br>
 +
You anticipate the possibility of a correction sent to the bender then...
 +
<br><br>
 +
Perform a RECALL '''before a MEASURE and BEST FIT'''
 +
 
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
A RECALL from a bender '''clears''' the results of a measure - so it is important to RECALL the latest bender data from the bender '''as a first step''' through Benderlink if the CLRA data in DOCS does not match the bender's LRA values.<br><br>
 +
 
 +
If the bender data has changed at the bender control before the current part is measured for correctness, then follow these steps:<br>
 +
<br>
 +
 
 +
#RECALL the latest tube data from the bender control<br><br>
 +
#MEASURE the tube and apply a tangent point fit<br><br>
 +
#CORRECT the Corrected LRA values by viewing the properties page, clicking on the CLRA tab, and pressing UPDATE.<br><br>
 +
#SEND the Corrected LRA values through Benderlink to the bender.
 +
 
 +
 
 +
</td>
 +
</tr>
 +
 
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#8085dc">
 +
</td>
 +
<td width=400 bgcolor="#8085dc">
 +
</td>
 +
</tr>
 +
 
 +
 
 +
<tr>
 +
<td bgcolor="#FFFFFF">
 +
After a RECALL from the bender...
 +
<br><br>
 +
...be careful to confirm that the incoming data changed the CLRA section of the data alone (and not the nominal LRA).
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
#If a matching part number is found in memory in DOCS, then DOCS applies the incoming bender data to the CORRECTED LRA data<br><br>
 +
#If the part number DOES NOT MATCH, then DOCs may assume that you intend to create a new MASTER part with the incoming data - and update the NOMINAL data.
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#8085dc">
 +
</td>
 +
<td width=400 bgcolor="#8085dc">
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td bgcolor="#FFFFFF">
 +
If you have a version of DOCS of 2.2 or 2.3 and previous to Dec 20, 2007 in file date, then...
 +
<br><br>
 +
be sure to upgrade before attempting corrections loops.
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Earlier DOCS versions of 2.3 change the NOMINAL LRA data during a RECALL(Only the CORRECTED LRA data should be updated.)
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#8085dc">
 +
</td>
 +
<td width=400 bgcolor="#8085dc">
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td bgcolor="#FFFFFF">
 +
DOCS reports a corrupted data transmission if the data from a RECALL DEFAULT TUBE has a diameter of ZERO.
 +
</td>
 +
<td bgcolor="#8ecaae">
 +
Be sure that the data at the bender has a non-zero diameter before attempting to RECALL data.
 +
</td>
 +
</tr>
 +
 
 +
<tr>
 +
<td width=200 bgcolor="#8085dc">
 +
</td>
 +
<td width=400 bgcolor="#8085dc">
 +
</td>
 +
</tr>
 +
 
 +
 
 +
</table>

Latest revision as of 15:29, 25 May 2017

Docs screen1.jpg

DOCS is a software package that is sold by Romer. The word "DOCS" means Data Overlay Camera System.




Contents

Screen Image

This is a screen image from DOCS software.

Romer docs egrtube.jpg

Solid Model Output

DOCS can output a solid model that can be imported into VTube-STEP. However it is our experience that the model is not as precise as models from other solid model programs (like SolidWorks).

Vtube-step 1 6.jpg

When calculating centerline data from DOCS solids, you may need to increase the projection tolerance value in the collection grid to make the calculation work.

Comparing DOCS to Supravision

Supravision and DOCS are developed by Romer. Supravision is the older legacy program for tube measurement. This matrix offers a comparison between the two software packages:

DOCS Software

Supravision Software

Active - Continued development

Static - No more development

Allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications

Measures only tube shapes

Because it is more powerful, it is also more complex. Thus - this software takes longer to learn.

Supravision is very easy to learn.

Can use contact or non-contact measurement

Can only use non-contact measurement of tube shapes

Can measure multiple tubes in a single DOCS file

Can measure one tube per Supravision file

Romer charges a fee for every bender connected to DOCS.

There is no charge from ROMER for connection through Supravision.

Tube Shop Manager (TSM) is an optional feature in DOCS. You must purchase TSM if you want to measure and correct tubes in DOCS software.

Tube measurement is standard in Supravision (because that is all Supravision can do).



Our Recommendation

As of December, 2007, we have been given a license of DOCS software for evaluation and testing with our Benderlink software. This is our recommendation:

  1. Be prepared for the increased complexity of the program.

  2. If you are a Supravision owner, then we recommend that you view DOCS in action before making a decision. Specifically ask for a tube demo. We also recommend that you compare DOCS to our VTube-LASER software before making a decision.

  3. Also, we recommend that our customers be careful to receive a quotation for all the options that you will expect with DOCS (like TSM and a sufficient number of bender licenses if you plan to connect to benders through Benderlink).



Communication with Supravision Network Protocol

See this link for information on which version of DOCS will communicate using SVNET: [1]

Principles for Corrections Loops with SVNET and DOCS

Principles

Reasons

If the data at the bender control has changed and...

You anticipate the possibility of a correction sent to the bender then...

Perform a RECALL before a MEASURE and BEST FIT

A RECALL from a bender clears the results of a measure - so it is important to RECALL the latest bender data from the bender as a first step through Benderlink if the CLRA data in DOCS does not match the bender's LRA values.

If the bender data has changed at the bender control before the current part is measured for correctness, then follow these steps:

  1. RECALL the latest tube data from the bender control

  2. MEASURE the tube and apply a tangent point fit

  3. CORRECT the Corrected LRA values by viewing the properties page, clicking on the CLRA tab, and pressing UPDATE.

  4. SEND the Corrected LRA values through Benderlink to the bender.


After a RECALL from the bender...

...be careful to confirm that the incoming data changed the CLRA section of the data alone (and not the nominal LRA).

  1. If a matching part number is found in memory in DOCS, then DOCS applies the incoming bender data to the CORRECTED LRA data.

  2. If the part number DOES NOT MATCH, then DOCs may assume that you intend to create a new MASTER part with the incoming data - and update the NOMINAL data.

If you have a version of DOCS of 2.2 or 2.3 and previous to Dec 20, 2007 in file date, then...

be sure to upgrade before attempting corrections loops.

Earlier DOCS versions of 2.3 change the NOMINAL LRA data during a RECALL. (Only the CORRECTED LRA data should be updated.)

DOCS reports a corrupted data transmission if the data from a RECALL DEFAULT TUBE has a diameter of ZERO.

Be sure that the data at the bender has a non-zero diameter before attempting to RECALL data.