Difference between revisions of "DOCS"
(→Screen Image) |
|||
(86 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
[[image:Docs_screen1.jpg|right]] | [[image:Docs_screen1.jpg|right]] | ||
− | DOCS is a software package that is sold by [[Romer]]. The word "DOCS" means Data Overlay Camera System. | + | DOCS is a software package that is sold by [[Romer]]. The word "DOCS" means Data Overlay Camera System. |
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
<br> | <br> | ||
+ | <br> | ||
+ | |||
+ | ==Screen Image== | ||
+ | This is a screen image from DOCS software.<br><br> | ||
+ | [[image:Romer_docs_egrtube.jpg|400px]] | ||
+ | |||
+ | ==Solid Model Output== | ||
+ | DOCS can output a solid model that can be imported into [[VTube-STEP]]. However it is our experience that the model is not as precise as models from other solid model programs (like SolidWorks). <br><br> | ||
+ | [[Image:Vtube-step_1_6.jpg|300px]]<br><br> | ||
+ | When calculating centerline data from DOCS solids, you may need to increase the projection tolerance value in the collection grid to make the calculation work. | ||
+ | <br><br> | ||
==Comparing DOCS to Supravision== | ==Comparing DOCS to Supravision== | ||
− | [[Supravision]] and DOCS are developed by | + | [[Supravision]] and DOCS are developed by [[Romer]]. [[Supravision]] is the older legacy program for tube measurement. This matrix offers a comparison between the two software packages: |
− | <table> | + | <table cellpadding="15"> |
<tr> | <tr> | ||
<td width=200 bgcolor="#e3e4f5"> | <td width=200 bgcolor="#e3e4f5"> | ||
− | DOCS Software | + | <font size=5>DOCS Software</font> |
</td> | </td> | ||
− | <td width=200 bgcolor="# | + | <td width=200 bgcolor="#cfe7dc"> |
− | Supravision Software | + | <font size=5>Supravision Software</font> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 27: | Line 34: | ||
<tr> | <tr> | ||
− | <td | + | <td bgcolor="#8085dc"> |
Active - Continued development | Active - Continued development | ||
</td> | </td> | ||
− | <td | + | <td bgcolor="#8ecaae"> |
Static - No more development | Static - No more development | ||
</td> | </td> | ||
Line 36: | Line 43: | ||
<tr> | <tr> | ||
− | <td | + | <td bgcolor="#8085dc"> |
Allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications | Allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications | ||
</td> | </td> | ||
− | <td | + | <td bgcolor="#8ecaae"> |
Measures only tube shapes | Measures only tube shapes | ||
</td> | </td> | ||
Line 45: | Line 52: | ||
<tr> | <tr> | ||
− | <td | + | <td bgcolor="#8085dc"> |
+ | Because it is more powerful, it is also more complex. Thus - this software takes longer to learn.</td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | Supravision is very easy to learn. | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#8085dc"> | ||
Can use contact or non-contact measurement | Can use contact or non-contact measurement | ||
</td> | </td> | ||
− | <td | + | <td bgcolor="#8ecaae"> |
Can only use non-contact measurement of tube shapes | Can only use non-contact measurement of tube shapes | ||
</td> | </td> | ||
Line 54: | Line 70: | ||
<tr> | <tr> | ||
− | <td | + | <td bgcolor="#8085dc"> |
Can measure multiple tubes in a single DOCS file | Can measure multiple tubes in a single DOCS file | ||
</td> | </td> | ||
− | <td | + | <td bgcolor="#8ecaae"> |
Can measure one tube per Supravision file | Can measure one tube per Supravision file | ||
</td> | </td> | ||
</tr> | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#8085dc"> | ||
+ | Romer charges a fee for every bender connected to DOCS. | ||
+ | </td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | There is no charge from ROMER for connection through Supravision. | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#8085dc"> | ||
+ | Tube Shop Manager (TSM) is an optional feature in DOCS. You must purchase TSM if you want to measure and correct tubes in DOCS software. | ||
+ | </td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | Tube measurement is standard in Supravision (because that is all Supravision can do). | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | |||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ==Our Recommendation== | ||
+ | As of December, 2007, we have been given a license of DOCS software for evaluation and testing with our [[Benderlink]] software. This is our recommendation: | ||
+ | <br><br> | ||
+ | #Be prepared for the increased complexity of the program.<br><br> | ||
+ | #If you are a Supravision owner, then we recommend that you view DOCS in action before making a decision. Specifically ask for a tube demo. We also recommend that you compare DOCS to our [[VTube-LASER]] software before making a decision.<br><br> | ||
+ | #Also, we recommend that our customers be careful to receive a quotation for '''all''' the options that you will expect with DOCS (like TSM and a sufficient number of bender licenses if you plan to connect to benders through Benderlink). | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ==Communication with Supravision Network Protocol== | ||
+ | |||
+ | See this link for information on which version of DOCS will communicate using SVNET: [http://www.advancedtubular.wiki/index.php?title=Supravision_Network_Protocol#DOC_Versions_to_Use_for_SVNET] | ||
+ | |||
+ | ==Principles for Corrections Loops with SVNET and DOCS== | ||
+ | |||
+ | |||
+ | <table cellpadding="15"> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#FFFFFF"> | ||
+ | <font size=5>Principles</font> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#cfe7dc"> | ||
+ | <font size=5>Reasons</font> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#FFFFFF"> | ||
+ | If the data at the bender control has changed and... | ||
+ | <br><br> | ||
+ | You anticipate the possibility of a correction sent to the bender then... | ||
+ | <br><br> | ||
+ | Perform a RECALL '''before a MEASURE and BEST FIT''' | ||
+ | |||
+ | </td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | A RECALL from a bender '''clears''' the results of a measure - so it is important to RECALL the latest bender data from the bender '''as a first step''' through Benderlink if the CLRA data in DOCS does not match the bender's LRA values.<br><br> | ||
+ | |||
+ | If the bender data has changed at the bender control before the current part is measured for correctness, then follow these steps:<br> | ||
+ | <br> | ||
+ | |||
+ | #RECALL the latest tube data from the bender control<br><br> | ||
+ | #MEASURE the tube and apply a tangent point fit<br><br> | ||
+ | #CORRECT the Corrected LRA values by viewing the properties page, clicking on the CLRA tab, and pressing UPDATE.<br><br> | ||
+ | #SEND the Corrected LRA values through Benderlink to the bender. | ||
+ | |||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#FFFFFF"> | ||
+ | After a RECALL from the bender... | ||
+ | <br><br> | ||
+ | ...be careful to confirm that the incoming data changed the CLRA section of the data alone (and not the nominal LRA). | ||
+ | </td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | #If a matching part number is found in memory in DOCS, then DOCS applies the incoming bender data to the CORRECTED LRA data. <br><br> | ||
+ | #If the part number DOES NOT MATCH, then DOCs may assume that you intend to create a new MASTER part with the incoming data - and update the NOMINAL data. | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#FFFFFF"> | ||
+ | If you have a version of DOCS of 2.2 or 2.3 and previous to Dec 20, 2007 in file date, then... | ||
+ | <br><br> | ||
+ | be sure to upgrade before attempting corrections loops. | ||
+ | </td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | Earlier DOCS versions of 2.3 change the NOMINAL LRA data during a RECALL. (Only the CORRECTED LRA data should be updated.) | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td bgcolor="#FFFFFF"> | ||
+ | DOCS reports a corrupted data transmission if the data from a RECALL DEFAULT TUBE has a diameter of ZERO. | ||
+ | </td> | ||
+ | <td bgcolor="#8ecaae"> | ||
+ | Be sure that the data at the bender has a non-zero diameter before attempting to RECALL data. | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td width=200 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | <td width=400 bgcolor="#8085dc"> | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
</table> | </table> |
Latest revision as of 15:29, 25 May 2017
DOCS is a software package that is sold by Romer. The word "DOCS" means Data Overlay Camera System.
Contents |
Screen Image
This is a screen image from DOCS software.
Solid Model Output
DOCS can output a solid model that can be imported into VTube-STEP. However it is our experience that the model is not as precise as models from other solid model programs (like SolidWorks).
When calculating centerline data from DOCS solids, you may need to increase the projection tolerance value in the collection grid to make the calculation work.
Comparing DOCS to Supravision
Supravision and DOCS are developed by Romer. Supravision is the older legacy program for tube measurement. This matrix offers a comparison between the two software packages:
DOCS Software |
Supravision Software |
Active - Continued development |
Static - No more development |
Allows for the measurement of tube data and non-tube data surrounding the tube - including brackets and other fabrications |
Measures only tube shapes |
Because it is more powerful, it is also more complex. Thus - this software takes longer to learn. |
Supravision is very easy to learn. |
Can use contact or non-contact measurement |
Can only use non-contact measurement of tube shapes |
Can measure multiple tubes in a single DOCS file |
Can measure one tube per Supravision file |
Romer charges a fee for every bender connected to DOCS. |
There is no charge from ROMER for connection through Supravision. |
Tube Shop Manager (TSM) is an optional feature in DOCS. You must purchase TSM if you want to measure and correct tubes in DOCS software. |
Tube measurement is standard in Supravision (because that is all Supravision can do). |
Our Recommendation
As of December, 2007, we have been given a license of DOCS software for evaluation and testing with our Benderlink software. This is our recommendation:
- Be prepared for the increased complexity of the program.
- If you are a Supravision owner, then we recommend that you view DOCS in action before making a decision. Specifically ask for a tube demo. We also recommend that you compare DOCS to our VTube-LASER software before making a decision.
- Also, we recommend that our customers be careful to receive a quotation for all the options that you will expect with DOCS (like TSM and a sufficient number of bender licenses if you plan to connect to benders through Benderlink).
Communication with Supravision Network Protocol
See this link for information on which version of DOCS will communicate using SVNET: [1]
Principles for Corrections Loops with SVNET and DOCS
Principles |
Reasons |
If the data at the bender control has changed and...
|
A RECALL from a bender clears the results of a measure - so it is important to RECALL the latest bender data from the bender as a first step through Benderlink if the CLRA data in DOCS does not match the bender's LRA values. If the bender data has changed at the bender control before the current part is measured for correctness, then follow these steps:
|
After a RECALL from the bender...
|
|
If you have a version of DOCS of 2.2 or 2.3 and previous to Dec 20, 2007 in file date, then...
|
Earlier DOCS versions of 2.3 change the NOMINAL LRA data during a RECALL. (Only the CORRECTED LRA data should be updated.) |
DOCS reports a corrupted data transmission if the data from a RECALL DEFAULT TUBE has a diameter of ZERO. |
Be sure that the data at the bender has a non-zero diameter before attempting to RECALL data. |