Difference between revisions of "VTube-LASER v2.9.9"
(→25pxNEW - SCP Feature (Stripe Cut Plane)) |
(→25pxOTHER CHANGES) |
||
(49 intermediate revisions by one user not shown) | |||
Line 6: | Line 6: | ||
==Revision 2.9.9== | ==Revision 2.9.9== | ||
− | Release Date: June | + | Release Date: June 15, 2018<br> |
− | Current Build: | + | Current Build: 3 |
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
Line 24: | Line 24: | ||
__TOC__ | __TOC__ | ||
− | ==[[image:Check.jpg|25px]]NEW - SCP Feature (Stripe Cut Plane)== | + | ==[[image:Check.jpg|25px]]NEW - SCP Feature (Stripe Cut Plane) - Eliminates LASER Stripe Data That Is Too Far From the Probe== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 30: | Line 30: | ||
<td width=400> | <td width=400> | ||
− | |||
− | + | The new STRIPE CUT PLANE feature is designed to eliminate entire laser stripes of data that are too far from the probe. It is included in the CUT PLANE CONTROL Window.<br><br> | |
+ | This is helpful for smaller parts because the scanners have an active depth range that allows them to pick up stripes that are within a 127mm (5 inch) inch range top to bottom.<br><br> | ||
+ | The goal of the SCP feature is to ensure that the scanner does not accidentally catch any object in a stripe that is far away from the first diameter relative to the probe - even when it stops pickup up near data. (See the image on the right.) | ||
− | + | <br><br> | |
− | SCP works with the | + | '''This is how SCP works with the other cut plane features:''' |
− | + | * FIRST, the CUT PLANE feature removes any laser-scanned surface data found below standard cut planes that are active.<br><br> | |
− | + | * SECOND, the DCP (DIAMETER CUT PLANE) feature removes the tails of laser-scanned stripes.<br><br> | |
− | + | * THIRD, the SCP (STRIPE CUT PLANE) feature then removes any laser-scanned stripe that is too far from the probe relative to the closest stripe to the probe.<br><br> | |
+ | <br><br> | ||
+ | Just like other cut plane features, the SCP feature is not used during tactile measurements with the ball probe. | ||
</td> | </td> | ||
Line 47: | Line 50: | ||
<td> | <td> | ||
− | [[image:VTube-LASER_v2.9. | + | [[image:VTube-LASER_v2.9.9_StripeCutPlaneWithLogo.png|300px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
Line 54: | Line 57: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]NEW - VTUBE-STEP MODE AUTOMATIC NEGATIVE STRAIGHT FIX DURING PARAMETRIC REBUILD== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 60: | Line 63: | ||
<td width=400> | <td width=400> | ||
− | |||
− | |||
− | |||
− | + | (Note: VTube-STEP is included in the VTube-LASER license. It is used for importing model data.)<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | Models with a 180-degree or greater bend angles can often create a very small negative straight distance value. We've added this feature to allow you to detect and fix this situation automatically by injecting a value of zero where there are negative straights.<br><br> | |
− | <br><br> | + | |
− | + | Pressing YES will change the shape of the part. However, if the negative straight is very small, then changing the shape will have no significance and will create a part that is close enough to the nominal to still be a good shape for use as MASTER data.<br><br> | |
− | < | + | This feature also allows you to skip the fix by pressing "NO." If you do this, then you can still manually adjust the radii to smaller values after the rebuild. Of course, if you skip this fix, then VTube may have trouble generating the diameter - and may even generate and display a program error that you can usually bypass.<br><br> |
− | < | + | |
− | + | </td> | |
− | + | ||
<td> | <td> | ||
− | |||
+ | [[image:vts_v2.9.9_automatic_negative_straight_fix_at_rebuild.png|600px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 90: | Line 83: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]FIX- CONSTRUCT TUBE FEATURE WORKS AGAIN== |
− | <table cellpadding=10 width= | + | <table cellpadding=10 width=1000> |
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | + | A customer discovered that the Construct Tube feature was not working in the previous version due to changes in the measuring code logic.<br><br>We fixed the broken code in this version. | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vtube-laer_v2.9.9_constructfeature.png|700px]]<br><br> |
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 113: | Line 100: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]FIX- VTUBE-STEP MODE COLLECTION SELECTION ISSUE== |
− | <table cellpadding=10 width= | + | <table cellpadding=10 width=1000> |
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | + | (Note: VTube-STEP is included in the VTube-LASER license. It is used for importing model data.)<br><br> | |
− | + | ||
− | + | ||
− | < | + | We found issues with the collected objects in VTube-STEP mode.<br><br> |
− | + | * For example, the selected collected object (see the orange object) would never delete from the screen - even if the operator selected it and pressed delete.<br><br> | |
+ | * This issue could cause index errors in the Collection Features list memory displayed in the grid.<br><br> | ||
+ | * The Collection Features Grid would not update automatically after a delete of the models on the screen.<br><br> | ||
− | + | All of these issues have been fixed. | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | + | [[image:vvts_2.9.9_collected_object_selection.png|700px]]<br><br> | |
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 149: | Line 123: | ||
</table> | </table> | ||
<br><br> | <br><br> | ||
− | |||
==[[image:Check.jpg|25px]]OTHER CHANGES== | ==[[image:Check.jpg|25px]]OTHER CHANGES== | ||
Line 157: | Line 130: | ||
<td width=800> | <td width=800> | ||
− | * | + | * VTube-LASER will stop a Construct Tube process with ROMER arms if the LASER mode is active. It will also issue a warning to turn the LASER off.<br><br> |
− | * The | + | * The laser stripe data is now displayed on the screen with lines between the points. This feature makes the stripes much easier to see on the screen.<br><br> |
</td> | </td> | ||
Latest revision as of 08:49, 14 June 2018
Revision 2.9.9Release Date: June 15, 2018
|
NEW - SCP Feature (Stripe Cut Plane) - Eliminates LASER Stripe Data That Is Too Far From the Probe
The new STRIPE CUT PLANE feature is designed to eliminate entire laser stripes of data that are too far from the probe. It is included in the CUT PLANE CONTROL Window.
This is how SCP works with the other cut plane features:
|
NEW - VTUBE-STEP MODE AUTOMATIC NEGATIVE STRAIGHT FIX DURING PARAMETRIC REBUILD
(Note: VTube-STEP is included in the VTube-LASER license. It is used for importing model data.) Models with a 180-degree or greater bend angles can often create a very small negative straight distance value. We've added this feature to allow you to detect and fix this situation automatically by injecting a value of zero where there are negative straights. Pressing YES will change the shape of the part. However, if the negative straight is very small, then changing the shape will have no significance and will create a part that is close enough to the nominal to still be a good shape for use as MASTER data. This feature also allows you to skip the fix by pressing "NO." If you do this, then you can still manually adjust the radii to smaller values after the rebuild. Of course, if you skip this fix, then VTube may have trouble generating the diameter - and may even generate and display a program error that you can usually bypass. |
FIX- CONSTRUCT TUBE FEATURE WORKS AGAIN
A customer discovered that the Construct Tube feature was not working in the previous version due to changes in the measuring code logic. |
FIX- VTUBE-STEP MODE COLLECTION SELECTION ISSUE
(Note: VTube-STEP is included in the VTube-LASER license. It is used for importing model data.) We found issues with the collected objects in VTube-STEP mode.
All of these issues have been fixed. |
OTHER CHANGES
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature