Difference between revisions of "VTube-LASER v2.9.10"
(→25pxNEW - LASER SCAN FILTER SOUND) |
(→25pxNEW LASER SCAN FILTER - MINIMUM NUMBER OF POINTS REQUIRED IN LASER STRIPES) |
||
(20 intermediate revisions by one user not shown) | |||
Line 6: | Line 6: | ||
==Revision 2.9.10== | ==Revision 2.9.10== | ||
− | Release Date: July | + | Release Date: July 5, 2018<br> |
− | Current Build: | + | Current Build: 14 |
* Back to [[VTube-LASER]] | * Back to [[VTube-LASER]] | ||
Line 33: | Line 33: | ||
Previous versions of VTube-LASER had no minimum point count per laser stripe. However, it helps to remove any LASER stripe that doesn't have enough data - because that often signals outlier points.<br><br> | Previous versions of VTube-LASER had no minimum point count per laser stripe. However, it helps to remove any LASER stripe that doesn't have enough data - because that often signals outlier points.<br><br> | ||
− | + | You can experiment with larger numbers to have a greater culling effect if you experience lone outliers.<br><br> | |
− | The new value can be entered and adjusted in the MEASURE SETUP / LASER tab menu.<br><br> | + | The new value can be entered and adjusted in the MEASURE SETUP / LASER tab menu. In this example, we entered "40" points required.<br><br> |
− | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe_closeup.png]] | + | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe_closeup.png]]<br><br> |
+ | |||
+ | The default minimum is now 5 points per stripe.<br><br> | ||
+ | |||
+ | [[image:laser stripe with 5 vertices minimum.png|400px]] | ||
+ | |||
+ | <br><br> | ||
+ | If you set the MINIMUM point count value in row 18 so that it is equal to or greater than the MAXIMUM count value in row 8, then no data will enter VTube-LASER, and VTube-LASER will play the LASER SCAN FILTER sound when you attempt a scan (see the new feature below). | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe.png|300px]] | + | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe.png|300px]] |
</td> | </td> | ||
Line 52: | Line 59: | ||
==[[image:Check.jpg|25px]]NEW - LASER SCAN FILTER SOUND== | ==[[image:Check.jpg|25px]]NEW - LASER SCAN FILTER SOUND== | ||
− | <table cellpadding=10 width= | + | <table cellpadding=10 width=900> |
<tr valign=top> | <tr valign=top> | ||
− | <td width= | + | <td width=500> |
In previous versions of VTube-LASER, the scanning sound goes silent if the SCAN BUTTON is pressed and no scan data is entering VTube-LASER.<br><br> | In previous versions of VTube-LASER, the scanning sound goes silent if the SCAN BUTTON is pressed and no scan data is entering VTube-LASER.<br><br> | ||
Line 92: | Line 99: | ||
* For the FARO scanner, this is the red button.<br><br><br> | * For the FARO scanner, this is the red button.<br><br><br> | ||
− | We | + | We redesigned the scanning engine so it no longer requires this in-range scanning position.<br><br><b>As of this version, VTube-LASER will watch for and react to the accept button press even if no laser data is incoming.</b> |
</td> | </td> | ||
Line 105: | Line 112: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]]NEW - HERBER Bender Corrections Through a Network== | + | ==[[image:Check.jpg|25px]]NEW - HERBER Bender Corrections Through a Network (VTube-LASER Only)== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 115: | Line 122: | ||
<br><br> | <br><br> | ||
[[image:HerberSplash.png|200px]]<br><br> | [[image:HerberSplash.png|200px]]<br><br> | ||
+ | |||
+ | <b>Bender corrections only work through VTube-LASER. (Not VTube-STEP)</b> | ||
+ | |||
+ | <br> | ||
+ | See [[VTube HERBER Bender Correction (MES Protocol)]] | ||
+ | |||
</td> | </td> | ||
Line 127: | Line 140: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]]NEW - HERBER Bender Setup From Solid Model Through a Network== | + | ==[[image:Check.jpg|25px]]NEW - HERBER Bender Setup From Solid Model Through a Network (VTube-LASER or VTube-STEP)== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 138: | Line 151: | ||
[[image:HerberSplash.png|200px]]<br><br> | [[image:HerberSplash.png|200px]]<br><br> | ||
− | Use this new feature to import solid models into HERBER bender controls. | + | Use this new feature to import solid models into HERBER bender controls.<br><br> |
+ | <b>Bender setup for the HERBER works through either VTube-LASER or VTube-STEP</b> | ||
+ | |||
+ | <br> | ||
+ | See [[VTube HERBER Bender New Part Setup (SOL Protocol)]] | ||
</td> | </td> | ||
Line 150: | Line 167: | ||
</table> | </table> | ||
<br><br> | <br><br> | ||
− | |||
==[[image:Check.jpg|25px]]NEW - VTUBE-LASER TUNED TO WORK WITH THE NEW FARO 6.1.2.7 USB DRIVER== | ==[[image:Check.jpg|25px]]NEW - VTUBE-LASER TUNED TO WORK WITH THE NEW FARO 6.1.2.7 USB DRIVER== | ||
Line 176: | Line 192: | ||
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
− | + | * VTube-STEP could give a list index error when loading the Assembly Control window. This has been fixed. | |
<td width=800> | <td width=800> | ||
Latest revision as of 04:44, 11 July 2018
Revision 2.9.10Release Date: July 5, 2018
|
NEW LASER SCAN FILTER - MINIMUM NUMBER OF POINTS REQUIRED IN LASER STRIPES
Previous versions of VTube-LASER had no minimum point count per laser stripe. However, it helps to remove any LASER stripe that doesn't have enough data - because that often signals outlier points. You can experiment with larger numbers to have a greater culling effect if you experience lone outliers. The new value can be entered and adjusted in the MEASURE SETUP / LASER tab menu. In this example, we entered "40" points required. The default minimum is now 5 points per stripe.
|
NEW - LASER SCAN FILTER SOUND
In previous versions of VTube-LASER, the scanning sound goes silent if the SCAN BUTTON is pressed and no scan data is entering VTube-LASER. There are two conditions that will trigger the LASER SCAN FILTER sound:
|
NEW - PRESS ACCEPT BUTTON WITHOUT AIMING AT THE PART
VTube-LASER operators know that previous versions of VTube-LASER require that you aim the LASER scanner at the part when you press the accept button at the end of a scan.
We redesigned the scanning engine so it no longer requires this in-range scanning position. |
NEW - HERBER Bender Corrections Through a Network (VTube-LASER Only)
NEW - HERBER Bender Setup From Solid Model Through a Network (VTube-LASER or VTube-STEP)
NEW - VTUBE-LASER TUNED TO WORK WITH THE NEW FARO 6.1.2.7 USB DRIVER
FARO USB driver 6.1.2.7 is a rewrite of the USB driver. It has many improvements that are very much worthwhile - like the scanner calibration is much improved.
|
OTHER CHANGES
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature