Difference between revisions of "VTube-LASER v2.9.15"
(→25pxNEW - END LENGTH FILTER - SHIFTS LENGTH CORRECTIONS BETWEEN A-END and B-END) |
(→25px OTHER CHANGES) |
||
(23 intermediate revisions by one user not shown) | |||
Line 30: | Line 30: | ||
<td width=300> | <td width=300> | ||
− | |||
− | |||
[[image:vtl_v2.9.15_EndLengthFilter_Graphic.png|200px]]<br><br> | [[image:vtl_v2.9.15_EndLengthFilter_Graphic.png|200px]]<br><br> | ||
+ | VTube-LASER now allows you to shift the total correction between ends using the End Length Filter menu in Bender Setup.<br><br> | ||
This feature resembles the End Tag feature in the original Supravision software.<br><br> | This feature resembles the End Tag feature in the original Supravision software.<br><br> | ||
− | It is particularly useful for any application that starts with large volumes of pre-cut tubing. There is no option for easily changing the tube length - so it is important to allow VTube-LASER to spread the total length change to the front straight, the back straight, or both evenly. | + | It is particularly useful for any application that starts with large volumes of pre-cut tubing. There is no option for easily changing the tube length - so it is important to allow VTube-LASER to spread the total length change during the correction process to the front straight, the back straight, or both evenly. |
</td> | </td> | ||
Line 47: | Line 46: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]FIX - IMPORTANT UPDATE for IMPORTING and MEASURING 180-DEGREE BENDS == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 53: | Line 52: | ||
<td width=300> | <td width=300> | ||
− | + | If you import models with 180-degree bends, then you will use the Split Bend COLLECTION feature in VTube-STEP.<br><br> | |
− | + | If you measure 180-degree bends, then you will use the Split Bend MEASURE feature in VTube-LASER.<br><br>Both of these features use the same Split Bend math engine.<br><br> | |
− | + | We discovered a problem that could cause the centerline of the Split Bend construction to be short by 0.020 inches (0.5 mm).<br><br> | |
− | + | If you use the Split Bend logic in VTube, then this update is critical for you because it addresses an issue we discovered during some research into Split Bend measuring issues with a customer.<br><br> | |
− | + | ||
− | + | ||
− | < | + | |
− | < | + | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | <br><br> | + | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image:vtl_v2.9. | + | [[image:vtl_v2.9.15_splitbend_import.png|600px]] |
</td> | </td> | ||
Line 89: | Line 68: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]]NEW - SUPRAVISION BATCH IMPORT - NOW USES YOUR DEFAULT SETUP TO BUILD PROJECT FILES == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 95: | Line 74: | ||
<td width=300> | <td width=300> | ||
− | + | The Supravision batch import can import any number of Supravision files at one time - building huge numbers of VTube project files in minutes.<br><br> | |
− | + | We added the ability for this batch engine to automatically use your current project default when importing the data. | |
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vts_v2.9.15_batch_sv_import.png|600px]] |
</td> | </td> | ||
Line 109: | Line 88: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] NEW - | + | ==[[image:Check.jpg|25px]] NEW - VTUBE-STEP NOW IMPORTS AUTODESK INVENTOR TUBE XYZ FILES == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 115: | Line 94: | ||
<td width=300> | <td width=300> | ||
− | + | Autodesk Inventor can create text files that contain the centerline XYZ data for a tube.<br><br> | |
− | + | VTube-STEP can now import these files. | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vts_2.9.15_autodesk_inventor_import.png|600px]] |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
Line 172: | Line 116: | ||
<td width=900> | <td width=900> | ||
− | * | + | *Fix - "Reset Point Labels" - The point labels no longer revert to the previous state if you save the project after a point label reset. |
+ | |||
+ | |||
</td> | </td> |
Latest revision as of 06:07, 9 October 2018
Revision 2.9.15Release Date: October 8, 2018
|
NEW - END LENGTH FILTER - SHIFTS LENGTH CORRECTIONS BETWEEN A-END and B-END
FIX - IMPORTANT UPDATE for IMPORTING and MEASURING 180-DEGREE BENDS
If you import models with 180-degree bends, then you will use the Split Bend COLLECTION feature in VTube-STEP. |
NEW - SUPRAVISION BATCH IMPORT - NOW USES YOUR DEFAULT SETUP TO BUILD PROJECT FILES
The Supravision batch import can import any number of Supravision files at one time - building huge numbers of VTube project files in minutes. |
NEW - VTUBE-STEP NOW IMPORTS AUTODESK INVENTOR TUBE XYZ FILES
Autodesk Inventor can create text files that contain the centerline XYZ data for a tube. |
OTHER CHANGES
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature