Difference between revisions of "VTube-LASER v2.9.16"

From ATTWiki
Jump to: navigation, search
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 2.9.16== Release Date: October 19, 2018<br> Current Build: 2 * Back to VTu...")
 
(25px Fix - Eaton Leonard Data Transfer to Additional Setup Window)
 
(12 intermediate revisions by one user not shown)
Line 24: Line 24:
 
__TOC__
 
__TOC__
  
==[[image:Check.jpg|25px]]NEW - END LENGTH FILTER - SHIFTS LENGTH CORRECTIONS BETWEEN A-END and B-END ==
+
==[[image:Check.jpg|25px]]NEW - Reverse XYZ Data and Reset Point Labels at the same time ==
  
 
<table cellpadding=10 width=1200>
 
<table cellpadding=10 width=1200>
Line 30: Line 30:
  
 
<td width=300>
 
<td width=300>
[[image:vtl_v2.9.15_EndLengthFilter_Graphic.png|200px]]<br><br>
+
VTube-LASER and STEP now allow for the centerline XYZ points and point labels to be reversed at the same time with a new feature in the XYZ popup menu.</td>
VTube-LASER now allows you to shift the total correction between ends using the End Length Filter menu in Bender Setup.<br><br>
+
This feature resembles the End Tag feature in the original Supravision software.<br><br>
+
It is particularly useful for any application that starts with large volumes of pre-cut tubing. There is no option for easily changing the tube length - so it is important to allow VTube-LASER to spread the total length change during the correction process to the front straight, the back straight, or both evenly.
+
</td>
+
  
 
<td>
 
<td>
[[image:vtl_2.9.15_EndLengthFilter.png|800px]]
+
[[image:vtl_v2.9.16_ReverseXYZandLabels.png|800px]]
 
</td>
 
</td>
  
Line 46: Line 42:
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]]FIX - IMPORTANT UPDATE for IMPORTING and MEASURING 180-DEGREE BENDS ==
+
==[[image:Check.jpg|25px]]Fix - Synchronize Reversed XYZ Data in STEP and LASER ==
  
<table cellpadding=10 width=1200>
+
<table cellpadding=10 width=1400>
 
<tr valign=top>
 
<tr valign=top>
  
 
<td width=300>
 
<td width=300>
If you import models with 180-degree bends, then you will use the Split Bend COLLECTION feature in VTube-STEP.<br><br>
+
When you have STEP and LASER open at the same time on multiple screens, it is possible to reverse either screen's XYZ coordinates. This fix updates both screens correctly when you reverse the coordinates in either screen.
If you measure 180-degree bends, then you will use the Split Bend MEASURE feature in VTube-LASER.<br><br>Both of these features use the same Split Bend math engine.<br><br>
+
We discovered a problem that could cause the centerline of the Split Bend construction to be short by 0.020 inches (0.5 mm).<br><br>
+
If you use the Split Bend logic in VTube, then this update is critical for you because it addresses an issue we discovered during some research into Split Bend measuring issues with a customer.<br><br>
+
  
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:vtl_v2.9.15_splitbend_import.png|600px]]
+
[[image:vtl_v2.9.16_STEPandLASER_Reverse.png|1000px]]
 
</td>
 
</td>
  
Line 68: Line 61:
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]]NEW - SUPRAVISION BATCH IMPORT - NOW USES YOUR DEFAULT SETUP TO BUILD PROJECT FILES ==
+
==[[image:Check.jpg|25px]]New - Import the EL Premier TOOL setup to VTube-LASER Bender Setup==
  
<table cellpadding=10 width=1200>
+
<table cellpadding=10 width=1400>
 
<tr valign=top>
 
<tr valign=top>
  
 
<td width=300>
 
<td width=300>
The Supravision batch import can import any number of Supravision files at one time - building huge numbers of VTube project files in minutes.<br><br>
+
Using the current tool setup at the EL Premier is very helpful - so that you don't have to re-enter the values after a first-time send to the bender. So now you can recall just the tool setup from the Premier in order to keep the current tool setup.
We added the ability for this batch engine to automatically use your current project default when importing the data.
+
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:vts_v2.9.15_batch_sv_import.png|600px]]
+
[[image:vts_v2.9.16_ELToolImportFromPremier.png|800px]]
 
</td>
 
</td>
  
Line 88: Line 80:
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]] NEW - VTUBE-STEP NOW IMPORTS AUTODESK INVENTOR TUBE XYZ FILES ==
+
==[[image:Check.jpg|25px]] Fix - Eaton Leonard Data Transfer to Additional Setup Window ==
  
<table cellpadding=10 width=1200>
+
<table cellpadding=10 width=1400>
 
<tr valign=top>
 
<tr valign=top>
  
 
<td width=300>
 
<td width=300>
Autodesk Inventor can create text files that contain the centerline XYZ data for a tube.<br><br>
+
We fixed a bug that prevented data that was recalled from the bender from being transferred to the Additional Data menu.
VTube-STEP can now import these files.
+
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:vts_2.9.15_autodesk_inventor_import.png|600px]]
+
[[image:vtl_2.9.16_bendersetup_addtionalELdata.png|800px]]
  
 
</td>
 
</td>
Line 107: Line 98:
 
</table>
 
</table>
  
<br><br>
 
 
==[[image:Check.jpg|25px]] OTHER CHANGES ==
 
 
<table cellpadding=10 width=900>
 
<tr valign=top>
 
 
<td width=900>
 
 
*Fix - "Reset Point Labels" - The point labels no longer revert to the previous state if you save the project after a point label reset.
 
 
 
 
</td>
 
 
<td>
 
</td>
 
 
</tr>
 
 
</table>
 
 
<br><br>
 
<br><br>
  

Latest revision as of 13:52, 1 November 2018

Vtube-laser logo 1.96.png


Revision 2.9.16

Release Date: October 19, 2018
Current Build: 2


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgNEW - Reverse XYZ Data and Reset Point Labels at the same time

VTube-LASER and STEP now allow for the centerline XYZ points and point labels to be reversed at the same time with a new feature in the XYZ popup menu.

Vtl v2.9.16 ReverseXYZandLabels.png



Check.jpgFix - Synchronize Reversed XYZ Data in STEP and LASER

When you have STEP and LASER open at the same time on multiple screens, it is possible to reverse either screen's XYZ coordinates. This fix updates both screens correctly when you reverse the coordinates in either screen.

Vtl v2.9.16 STEPandLASER Reverse.png



Check.jpgNew - Import the EL Premier TOOL setup to VTube-LASER Bender Setup

Using the current tool setup at the EL Premier is very helpful - so that you don't have to re-enter the values after a first-time send to the bender. So now you can recall just the tool setup from the Premier in order to keep the current tool setup.

Vts v2.9.16 ELToolImportFromPremier.png



Check.jpg Fix - Eaton Leonard Data Transfer to Additional Setup Window

We fixed a bug that prevented data that was recalled from the bender from being transferred to the Additional Data menu.

Vtl 2.9.16 bendersetup addtionalELdata.png