Difference between revisions of "VTube-LASER v2.8.3"
(→25px ENHANCED: MOVED CORRECTION DAMPING TO TAB MENU) |
(→25px NEW: INCREASE LRA ROW COUNT in BENDER SETUP for EXTRA OPERATIONS LIKE END TRIM) |
||
Line 29: | Line 29: | ||
<td width=300> | <td width=300> | ||
The LRA ROW COUNT in Bender Setup can now be increased in order to allow for extra operations at the end of the bender cycle.<br><br> | The LRA ROW COUNT in Bender Setup can now be increased in order to allow for extra operations at the end of the bender cycle.<br><br> | ||
− | For example, this two-bend part, after adding a row, has four LRA rows. The added row has a new 2 inch leg for end trimming. You can manually adjust the distance in the extra row for clamping the tube for marking | + | For example, this two-bend part, after adding a row, has four LRA rows. The added row has a new 2 inch leg for end trimming. You can manually adjust the distance in the extra row for clamping the tube for trim marking.<br><br> |
The manually entered data in this extra row is saved with the project (ie., the 2 inches in the last row). | The manually entered data in this extra row is saved with the project (ie., the 2 inches in the last row). | ||
<td> | <td> |
Revision as of 23:33, 8 June 2017
Revision 2.8.3Original Release Date: June 8, 2017
|
NEW: INCREASE LRA ROW COUNT in BENDER SETUP for EXTRA OPERATIONS LIKE END TRIM
The LRA ROW COUNT in Bender Setup can now be increased in order to allow for extra operations at the end of the bender cycle. |
NEW: MULTISCREEN SUPPORT
In previous versions, VTube could only be run from the main screen and report images would only print properly if VTube was running on the main screen. Now VTube-STEP and VTube-LASER supports multi-screen setups. |
NEW: VTube-LASER WINDOW NOW MINIMIZES TO TASKBAR
In previous versions, the VTube-LASER window could only be minimized as a reduced window in the lower left corner of the screen. |
FIX: IMPORTED MODEL DELETION ISSUE RESOLVED
VTube would randomly delete the imported model after a parametric data build. This has been fixed. |
ENHANCED: MOVED BENDER SETUP CORRECTION DAMPING TO TAB MENU
We moved the CORRECTION DAMPING feature in BENDER SETUP into its own tab menu to save screen space. |
NEW: Addata ZModem Communications Protocol
We've added an Addata ZModem communications protocol also known as the Addison "Non-Standard Device Interface". |
This protocol allows you to setup the COM port configuration to match the configuration at the other end of the serial port connection. Set the protocol to Addata ZModem, then click on the COM port cell to display this COM port configuration dialog.
See VTube-LASER Addata ZModem Communications Protocol for more information. |
ENHANCED: NUMALLIANCE BENDER OUTPUT HANDLES 180-DEGREE BENDS
OUTPUTS 180-DEGREE BENDS
OUTPUTS SPRINGBACK-COMPENSATED DATA
|
ENHANCED: SUPRAVISION IMPORT HANDLES DATA WITH NO CENTERLINE XYZ POINTS
VTube requires XYZ coordinates for the parametric tube data. |
ENHANCED: DOCS IMPORT SETS THE PART NUMBER to the INCOMING FILENAME
Previous versions of VTube would use the actual DOCS part number of "Part 1", "Part 2", etc., in the VTube Part Number. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature