Difference between revisions of "VTube-LASER v2.8.4"

From ATTWiki
Jump to: navigation, search
(25px IMPROVED: REVERSE CALC)
(25px IMPROVED: REVERSE CALC)
Line 48: Line 48:
 
The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.<br><br>
 
The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.<br><br>
 
The math engine has been improved to handle this condition.
 
The math engine has been improved to handle this condition.
 +
<td>
 +
[[image:vtube-laser_2.9.4_reverse calc.png|400px]]
 +
</td>
 +
<td>
 +
</tr>
 +
</table>
 +
 +
 +
==[[image:Check.jpg|25px]] NEW DATUM REPORTS POSSIBLE==
 +
 +
<table cellpadding=10 width=900>
 +
<tr valign=top>
 +
<td width=300>
 +
Now VTube-LASER can show DATUM reports with Measured-aligned distances to MASTER Datums.<br><br>
 +
<br><br>
 +
To use these new report templates:<br><br>
 +
# Download these two new templates: [https://www.advancedtubular.com/customers/vtube/vtubelaser_v2.9.4_datum_measured2master_report_templates.zip]*
 +
# Extract them to a folder location that you can find.
 +
# Load VTube-LASER.
 +
# Go to Reports
 +
# Click on the Templates tab.
 +
# Click on Import.
 +
# Find and click on the new Datum templates.
 +
# Repeat for the second template file.
 +
 
<td>
 
<td>
 
[[image:vtube-laser_2.9.4_reverse calc.png|400px]]
 
[[image:vtube-laser_2.9.4_reverse calc.png|400px]]

Revision as of 00:00, 23 June 2017

Vtube-laser logo 1.96.png


Revision 2.8.4

Original Release Date: June 22, 2017
Latest Build: 1


Vtube-laser v2.7 screenshot.png

Contents


Check.jpg NEW: MULTISCREEN "SWITCH SCREEN" BUTTONS

When multiple screens are present, then VTube now adds "SWITCH SCREEN" buttons in the toolbars.

See VTube-LASER Multiple Screen Support for details.

Vtl v2.9 switchscreensbutton.png

Multi-screen support - STEP and LASER.png

Check.jpg IMPROVED: REVERSE CALC

In previous versions, when performing REVERSE CALC from bender data to centerline XYZ data, VTube-LASER could not keep the previous part orientation in 3D space when the first leg ran parallel to the Z axis.

The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.

The math engine has been improved to handle this condition.

Vtube-laser 2.9.4 reverse calc.png


Check.jpg NEW DATUM REPORTS POSSIBLE

Now VTube-LASER can show DATUM reports with Measured-aligned distances to MASTER Datums.



To use these new report templates:

  1. Download these two new templates: [1]*
  2. Extract them to a folder location that you can find.
  3. Load VTube-LASER.
  4. Go to Reports
  5. Click on the Templates tab.
  6. Click on Import.
  7. Find and click on the new Datum templates.
  8. Repeat for the second template file.

Vtube-laser 2.9.4 reverse calc.png

Other Pages