Difference between revisions of "VTube-LASER v2.9.7"
From ATTWiki
(→25pxNEW - Automatic Offer to Copy Measured to Master If No Master is Present) |
(→25pxNEW - Measured Tube Averaging (MTA) Features in User Interface) |
||
Line 43: | Line 43: | ||
==[[image:Check.jpg|25px]]NEW - Measured Tube Averaging (MTA) Features in User Interface== | ==[[image:Check.jpg|25px]]NEW - Measured Tube Averaging (MTA) Features in User Interface== | ||
+ | |||
+ | <table cellpadding=10 width=800> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=400> | ||
+ | The MTA feature now tracks and reports the number of tube measures previously measured in the tube measure control.<br><br> | ||
+ | MTA now also automatically enters the number of measures in the MTA averaging dialog. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:VTube-LASER-v2.97_MTAtrackdisplay.png|200px]] | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - Tube Control Window - Buttons Hide and Display Based on Context== | ||
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> |
Revision as of 19:03, 30 March 2018
Revision 2.9.7Release Date: March 30, 2018
|
NEW - Automatic Offer to Copy Measured to Master If No Master is Present
We had the opportunity to measure a customer's inventory of over 130 parts in a reverse-engineering project. So added the feature that detects empty MASTER data and offers to copy the MEASURED data automatically after a reverse-engineer measurement. |
NEW - Measured Tube Averaging (MTA) Features in User Interface
The MTA feature now tracks and reports the number of tube measures previously measured in the tube measure control. |
NEW - Tube Control Window - Buttons Hide and Display Based on Context
The MTA feature now tracks and reports the number of tube measures previously measured in the tube measure control. |
NEW - AB Length Tolerances in the Reports
We added AB Length + and - tolerances to VTube-LASER reports too. |
NEW- SUPRAVISION STYLE OOT CHARACTER
NEW - GO DIRECTLY TO PRINT REPORT BUTTON
We added a new button in the report menus that let you go directly to the print dialog. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature