Difference between revisions of "VTube-LASER v2.9.12"

From ATTWiki
Jump to: navigation, search
(Follow these steps to setup VTube-LASER to split a bend then turn on "Split Bend Measuring")
(25pxNEW - LRA POPUP MENU SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION)
Line 24: Line 24:
 
__TOC__
 
__TOC__
  
==[[image:Check.jpg|25px]]NEW - LRA POPUP MENU SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION ==
+
==[[image:Check.jpg|25px]]NEW - LRA POPUP MENU COMMAND SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION ==
  
 
<table cellpadding=10 width=1200>
 
<table cellpadding=10 width=1200>
Line 36: Line 36:
  
 
<td>
 
<td>
[[image:vtl_v2.9.12_split_bend_into_two_adjacent.png|400px]]
+
[[image:vtl_v2.9.12_splitbend_into_twobends.png|400px]]
</td>
+
 
+
<td>
+
[[image:Split Bend Angle Into Two Bends - Slide 2.png|400px]]
+
 
</td>
 
</td>
  

Revision as of 16:25, 13 August 2018

Vtube-laser logo 1.96.png


Revision 2.9.12

Release Date: August 13, 2018
Current Build: 1


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgNEW - LRA POPUP MENU COMMAND SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION

Splitting a bend into two adjacent half-bends manually is a bit complex. So we added this command to make it easy.

This new "split a bend" command is useful for when a very high bend angle throws its intersection point far from the tube and then creates unreliably high swings in the tangent deviation and bender correction data.

After splitting a bend into two adjacent half-bends, you can use the SPLIT BEND measuring feature to scan the inside and outside of the actual bend to overcome this problem.

Vtl v2.9.12 splitbend into twobends.png



Follow these steps to setup VTube-LASER to split a bend then turn on "Split Bend Measuring"

1 - Select the bend to split in an LRA grid.

2 - Right click.

3 - Choose "Split Selected Bend into Two Bends"

4 - In the Bend Setup tab above the XYZ data, click on Split Bend Setup.

5 - In the Split Bend Setup window, set the STRAIGHT with the ZERO straight length to "Split Bend at Apex" (It will equal the BEND number + 1). Watch the data compress and highlight in the LRA grid when you exit the window.


VTube-LASER will now be ready to measure with the Split Bend scanning feature.

See VTube-LASER Split Bend Feature for details on the Split Bend measuring feature.

Split Bend - Bend Setup for Split Bend USAF.png



Check.jpg OTHER CHANGES



Other Pages