Difference between revisions of "VTube-LASER v2.9.12"

From ATTWiki
Jump to: navigation, search
(25pxNEW - LRA POPUP MENU COMMAND SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION)
Line 38: Line 38:
 
* Springback Compensated LRA
 
* Springback Compensated LRA
 
* Absolute LRA
 
* Absolute LRA
 +
</td>
 +
 +
<td>
 +
[[image:vtl_v2.9.12_splitbend_into_twobends.png|800px]]
 +
</td>
 +
 +
</tr>
 +
 +
</table>
 +
<br><br>
 +
 +
<table cellpadding=10 width=1200>
 +
<tr valign=top>
 +
 +
<td width=300>
 +
===Follow these steps to setup VTube-LASER to split a bend then turn on "Split Bend Measuring"===
 +
 +
1 - Select the bend to split in an LRA grid.<br><br>
 +
2 - Right click.<br><br>
 +
3 - Choose "Split Selected Bend into Two Bends"<br><br>
 +
4 - In the Bend Setup tab above the XYZ data, click on Split Bend Setup.<br><br>
 +
5 - In the Split Bend Setup window, set the STRAIGHT with the ZERO straight length to "Split Bend at Apex" (It will equal the BEND number + 1). Watch the data compress and highlight in the LRA grid when you exit the window.<br><br><br>
 +
VTube-LASER will now be ready to measure with the Split Bend scanning feature.<br><br>
 +
 +
See [[VTube-LASER Split Bend Feature]] for details on the Split Bend measuring feature.
 +
 +
</td>
 +
 +
<td>
 +
 +
[[image:Split Bend - Bend Setup for Split Bend USAF.png|800px]]
 +
</td>
 +
 +
</tr>
 +
 +
 +
</table>
 +
<br><br>
 +
 +
 +
 +
 +
 +
==[[image:Check.jpg|25px]]NEW - MINIMUM CLAMP LENGTH FILTER FOR CORRECTIONS ==
 +
 +
<table cellpadding=10 width=1200>
 +
<tr valign=top>
 +
 +
<td width=300>
 +
This new filter is in a new CORRECTIONS FILTER tab menu in Bender Setup.<br><br>
 +
We added this feature into Bender Setup to allow VTube-LASER to limit the shortening changes made to lengths between bends. For example, if the minimum clamp length is 50 mm and this filter is active, then any LENGTH correction that calculates a length less than 50 mm will be reset to the minimum of 50.<br><br>
 +
 +
When the filter limits the length reduction, then a dialog will appear before data is sent to the bender. The dialog will warn you with a message that at least one length correction was limited to the minimum clamp length.<br><br>
 
</td>
 
</td>
  

Revision as of 12:59, 14 August 2018

Vtube-laser logo 1.96.png


Revision 2.9.12

Release Date: August 13, 2018
Current Build: 1


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgNEW - LRA POPUP MENU COMMAND SPLITS ONE BEND INTO TWO FOR MORE ACCURATE MEASURING QUALIFICATION and BENDER CORRECTION

Splitting a bend into two adjacent half-bends manually is a bit complex. So we added this command to make it easy.

This new "split a bend" command is useful for when a very high bend angle throws its intersection point far from the tube and then creates unreliably high swings in the tangent deviation and bender correction data.

After splitting a bend into two adjacent half-bends, you can use the SPLIT BEND measuring feature to scan the inside and outside of the actual bend to overcome this problem.

This new command is available in these grids:

  • Incremental LRA
  • Springback Compensated LRA
  • Absolute LRA

Vtl v2.9.12 splitbend into twobends.png



Follow these steps to setup VTube-LASER to split a bend then turn on "Split Bend Measuring"

1 - Select the bend to split in an LRA grid.

2 - Right click.

3 - Choose "Split Selected Bend into Two Bends"

4 - In the Bend Setup tab above the XYZ data, click on Split Bend Setup.

5 - In the Split Bend Setup window, set the STRAIGHT with the ZERO straight length to "Split Bend at Apex" (It will equal the BEND number + 1). Watch the data compress and highlight in the LRA grid when you exit the window.


VTube-LASER will now be ready to measure with the Split Bend scanning feature.

See VTube-LASER Split Bend Feature for details on the Split Bend measuring feature.

Split Bend - Bend Setup for Split Bend USAF.png





Check.jpgNEW - MINIMUM CLAMP LENGTH FILTER FOR CORRECTIONS

This new filter is in a new CORRECTIONS FILTER tab menu in Bender Setup.

We added this feature into Bender Setup to allow VTube-LASER to limit the shortening changes made to lengths between bends. For example, if the minimum clamp length is 50 mm and this filter is active, then any LENGTH correction that calculates a length less than 50 mm will be reset to the minimum of 50.

When the filter limits the length reduction, then a dialog will appear before data is sent to the bender. The dialog will warn you with a message that at least one length correction was limited to the minimum clamp length.

Vtl v2.9.12 splitbend into twobends.png



Follow these steps to setup VTube-LASER to split a bend then turn on "Split Bend Measuring"

1 - Select the bend to split in an LRA grid.

2 - Right click.

3 - Choose "Split Selected Bend into Two Bends"

4 - In the Bend Setup tab above the XYZ data, click on Split Bend Setup.

5 - In the Split Bend Setup window, set the STRAIGHT with the ZERO straight length to "Split Bend at Apex" (It will equal the BEND number + 1). Watch the data compress and highlight in the LRA grid when you exit the window.


VTube-LASER will now be ready to measure with the Split Bend scanning feature.

See VTube-LASER Split Bend Feature for details on the Split Bend measuring feature.

Split Bend - Bend Setup for Split Bend USAF.png



Check.jpg OTHER CHANGES



Other Pages