Difference between revisions of "VTube-LASER v2.9.17"
(→25pxFIX - Split Bend Corrections in Bend Setup (Important fix for 180-degree bend correction)) |
(→25pxNEW- Auto Disconnect When Driver is Busy) |
||
Line 120: | Line 120: | ||
− | ==[[image:Check.jpg|25px]]NEW- Auto Disconnect When Driver is Busy == | + | ==[[image:Check.jpg|25px]]NEW- Auto Disconnect When the FARO Driver is Busy == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 132: | Line 132: | ||
<td> | <td> | ||
[[image:vtl_v2.9.17_FAROAutoCloseConnectionWhenBusy.png|700px]] | [[image:vtl_v2.9.17_FAROAutoCloseConnectionWhenBusy.png|700px]] | ||
+ | </td> | ||
+ | |||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW- Auto Display of DRO (Digital Readout) When Moving from VTube-STEP to VTube-LASER == | ||
+ | |||
+ | <table cellpadding=10 width=1200> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | When the arm is connected to VTube, and the user changes from VTube-STEP to VTube-LASER, VTube now automatically displays the DRO. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:vtl_v2.9.17_DRO.png|700px]] | ||
</td> | </td> | ||
Revision as of 03:38, 6 December 2018
Revision 2.9.17Release Date: Unreleased
|
NEW - Scan and Measure Point Clouds
VTube-LASER now handles point clouds in storage we call "buckets." This allows you to scan anything into VTube-LASER - not just tubes. With this feature:
|
NEW - Automatic Reset Straight Count at Measure
If VTube-LASER starts a measure setup with ZERO straights, then it automatically resets to the MASTER straight count. |
NEW - MAX Points for Cylinder Stripes Is Now 50
Through some experimentation, any point count above 50 per stripe is not helpful in VTube-LASER. For example, as you approach 1000 points per stripe, it slows the math engine significantly and actually causes more Cylinder Fit problems than it solves. |
FIX - Split Bend Corrections in Bend Setup (Important fix for 180-degree bend correction)
The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to 180-degree bends. |
NEW- Auto Disconnect When the FARO Driver is Busy
When the FARO driver is busy with other connections (like to CAM2), VTube-LASER would give an error then shutdown. |
NEW- Auto Display of DRO (Digital Readout) When Moving from VTube-STEP to VTube-LASER
When the arm is connected to VTube, and the user changes from VTube-STEP to VTube-LASER, VTube now automatically displays the DRO. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature