Difference between revisions of "VTube-LASER v2.9.17"

From ATTWiki
Jump to: navigation, search
(25pxNEW - Automatic Reset Straight Count at Measure)
(25pxNEW - VTube-LASER Now Automatically Resets Straight Count at Measure)
Line 32: Line 32:
  
 
<td width=300>
 
<td width=300>
If VTube-LASER starts a measure setup with ZERO straights, then it automatically resets to the MASTER straight count.<br><br>
+
Users are used to entering the number of straights before measuring in the Tube Measure Setup menu.<br><br>
 +
You won't have to do that any more. Now, if VTube-LASER starts a measure setup with ZERO straights, then it automatically resets to the MASTER straight count.<br><br>
 
</td>
 
</td>
  

Revision as of 01:52, 21 December 2018

Vtube-laser logo 1.96.png


Revision 2.9.17

Release Date: Unreleased
Current Build: 8


Vtube-laser v2.7 screenshot.png

Contents



Check.jpgNEW - VTube-LASER Now Automatically Resets Straight Count at Measure

Users are used to entering the number of straights before measuring in the Tube Measure Setup menu.

You won't have to do that any more. Now, if VTube-LASER starts a measure setup with ZERO straights, then it automatically resets to the MASTER straight count.

Vtl v2.9.17 SetupMeasureResetStraightCount.png



Check.jpgNEW - Scan and Measure Point Clouds (Experimental)

This feature is considered experimental - which means we will be testing it further and adding more functionality to it.

VTube-LASER now handles point clouds in storage we call "buckets." This allows you to scan anything into VTube-LASER - not just tubes.

With this feature:

  • Scan point clouds into list of point cloud buckets using the LASER scanner.
  • Turn buckets of points on our off.
  • Select points on the screen then press DELETE to delete them from the buckets.
  • Measure the distance between any two points.
  • Transfer the point clouds into SOLIDWORKS.
  • Transfer the point clouds into an ASCII file for use in any other program.
  • Point clouds are stored and recalled to/from the VTube-LASER project file.
  • Point cloud changes are stored in the UNDO memory. If you delete the wrong set of points - just press UNDO.
  • Set the color of each bucket of point clouds.


Vtl v2.9.17 PointCloudDimension.png



Check.jpgNEW- Store "Named Setups" for the Cylinder Fit (Measure 1) Menu in System Options

The new "named setup" feature allows you to store cylinder fit tolerances in Measure 1 for measuring cylinders for use in other projects. Each setup is stored in a list of named setups that can be used in any other project.

For example you could store a unique setup for measuring tubes with armor (like on brake lines) and another default one for regular tubes.

Vtl v2.9.17 Measure1NamedSetups.png




Check.jpgNEW - MAX Points for Cylinder Stripes Is Now 50

Through some experimentation, any point count above 50 per stripe is not helpful in VTube-LASER. For example, as you approach 1000 points per stripe, it slows the math engine significantly and actually causes more Cylinder Fit problems than it solves.

VTube-LASER will now allow up to 50 points per stripe for measuring cylinders - never more.

Vtl v2.9.17 Max50PointsPerStripeForCylinders.png



Check.jpgFIX - Split Bend Corrections for Bender Communications in Bender Setup (Important fix for 180-degree bend correction)

This is important for you if you automatically correct benders with 180-degree bends

The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to 180-degree bends.

Also, the wrong number of rows was sent to Bender Setup - which meant that correction data was not properly aligned with the data at the bender. For example, for a single 180-degree bend part, there should only be two correction rows. However, VTube was sending three rows of data for two 90-degree bends.

This has been fixed in this version.

See the resulting correction data grid in the Bender Setup screen below the image.

Vtl v2.9.17 180degreeSplitBend BenderSetupCorrectionFix.png



Check.jpgNEW- Auto Disconnect When the FARO Driver is Busy

When the FARO driver is busy with other connections (like to CAM2), VTube-LASER would give an error then shutdown.

Now VTube-LASER closes the connection to the FARO arm and displays a message with a sound to let you know that the connection is closed.

Vtl v2.9.17 FAROAutoCloseConnectionWhenBusy.png




Check.jpgNEW- Auto Display of DRO (Digital Readout) When Moving from VTube-STEP to VTube-LASER

When the arm is connected to VTube, and the user changes from VTube-STEP to VTube-LASER, VTube now automatically displays the DRO window (Digital Readout).

Vtl v2.9.17 DRO.png



Check.jpgOther Changes

  • For HTML reports, the screen-image bmp file is now only copied to the html export folder when it is present in the html report.
  • In VTube-STEP, the export html report feature would display an error and would not save he html reports. This has been fixed.