Difference between revisions of "VTube-LASER v2.9.18"
(→25pxNEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode) |
(→25pxNEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode) |
||
Line 37: | Line 37: | ||
These are the working rules for the method: | These are the working rules for the method: | ||
− | *This mode only works with parts that have MASTER data. | + | *This mode only works with parts that have MASTER data.<br><br> |
− | *If a part does not have MASTER data (like in Reverse Engineering), then the regular UniScan Cylinder Separation Distance value is used. | + | *If a part does not have MASTER data (like in Reverse Engineering), then the regular UniScan Cylinder Separation Distance value is used.<br><br> |
− | *If the separation distance is ever less than 0.004" (100 microns), then the value reverts to 100 microns. | + | *If the separation distance is ever less than 0.004" (100 microns), then the value reverts to 100 microns.<br><br> |
− | *If the MASTER length is less than or equal to ZERO, then the separation value reverts to the regular UniScan Cylinder Separation Distance value. | + | *If the MASTER length is less than or equal to ZERO, then the separation value reverts to the regular UniScan Cylinder Separation Distance value.<br><br> |
</td> | </td> | ||
Revision as of 00:12, 9 March 2019
Revision 2.9.18Release Date: February 2, 2019
|
Contents |
NEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode
The NEW AUTOMATIC LASER SEPARATION method allows VTube-LASER to automatically control the separation distance between laser stripes based on the known MASTER tube length. These are the working rules for the method:
|
NEW - Bender Setup Window CORRECTION MAPPING Adds Flexibility to Corrections
Use correction mapping in Bender Setup to move corrections up or down columns and to ignore specific corrections.
|
NEW - COMCO CSV Communications Protocol
This protocol allows you to correct COMCO benders through the CSV file import and export. |
NEW - Now VTube has THREE Default Radii
Radius 1, Radius 2, and Radius 3 are now available in Part Setup. |
FIX - The Taskbar Icon Now Displays
VTube-LASER users discovered that the taskbar icon did not always display. This has been fixed. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature