Difference between revisions of "VTube-LASER v3"
(→The Scan Score Protects Users from Poor Scans) |
(→The Scan Score Protects Users from Poor Scans) |
||
Line 59: | Line 59: | ||
As the historical list of Cylinder Fit values grows, the scan score becomes more helpful.<br><br> | As the historical list of Cylinder Fit values grows, the scan score becomes more helpful.<br><br> | ||
If, for example, the overall scan score is based on 1000 measures, and your overall score on the last measure is 75%, then it is reasonable to conclude that something is wrong with the last tube measure - and you should rescan the tube before accepting the measured data as certain.<br><br> | If, for example, the overall scan score is based on 1000 measures, and your overall score on the last measure is 75%, then it is reasonable to conclude that something is wrong with the last tube measure - and you should rescan the tube before accepting the measured data as certain.<br><br> | ||
− | In the example on the right, we covered a section of the last straight with highly-deformed metal tape, and then used that shape to measure the cylinder for the last straight. The result of the overall score was a 75%. As you can see, the last straight fails the qualification in this measure. | + | In the example on the right, we covered a section of the last straight with highly-deformed metal tape, and then used that shape to measure the cylinder for the last straight. The result of the overall score was a 75%. As you can see, the last straight fails the qualification in this measure. The low scan score is an indicator that the measure was poor and should not be accepted. |
</td> | </td> | ||
<td> | <td> |
Revision as of 16:56, 8 July 2020
Version 3Release Date: July 15, 2020
|
Contents |
NEW INVENTION - The SCAN SCORE
We've invented a way for users to score their last scan based on all historical data. The feature is called SCAN SCORE. |
How the Scan Score is Calculated
All the Cylinder Fit values from each completed measure are stored in the project file and then used to create scores for each attribute on each straight. |
The Scan Score Protects Users from Poor Scans
As the historical list of Cylinder Fit values grows, the scan score becomes more helpful. |
Other Changes
- For HTML reports, the screen-image bmp file is now only copied to the html export folder when it is present in the html report.
- In VTube-STEP, the export html report feature would display an error and would not save he html reports. This has been fixed.
- Auto disconnect without critical error or crash when FARO driver stops answering VTube-LASER's requests for information.
- A change allows for hardware keys (dongles) with serial numbers greater than 2.147 billion. Older revisions may not read new hardware key serial numbers properly if they exceed that value. This version addresses that issue.
- The Language Editor reloads from the main user interface much faster than previous versions. (Build 32)
- Optimized the STEP mode and LASER mode default settings to make VTube faster in its default state. (Build 33)
- Fixed show unbend only in STEP mode (Build 39)
- Measure guide viewport window does not display when the MASTER tube point count is 0.
- Fixed connection to the FARO driver for older Edge arms
- Added DOCS file import file checks
- This version was modified to run with FARO driver version 6.2.1.9
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature