[IF] AND, input=not(Input_AutoLoader_PartPresent_End), input=Input_AutoLoader_PartPresent2_End, output=not(Output_AutoLoader_GripperClose_Constant) | [IF] AND, input=not(Input_AutoLoader_PartPresent_End), input=Input_AutoLoader_PartPresent2_End, output=not(Output_AutoLoader_GripperClose_Constant) | ||
Revision as of 15:41, 28 August 2009
NEW - CYCLE HOLD for Secondary Processes
In previous versions, "[CYCLEHOLD]" had no effect inside secondary processes that control devices around the bender. Now hoppers and side loaders can put the entire cell into the regular cycle hold state.
This is a snippet from a secondary processlist that shows this feature in action:
[IF] AND, input=not(Input_AutoLoader_PartPresent_End), input=Input_AutoLoader_PartPresent2_End, output=not(Output_AutoLoader_GripperClose_Constant) [Immediate_Message] AUTOLOADER PART NEST JAMMED - Entering CYCLE HOLD [CYCLEHOLD] [END]
ENHANCED - AutoLoader Timeout is Tied to Robot Timeout
The Robot Timeout value in the Low Level dynamic options is now used to control the AutoLoader timeouts.