Difference between revisions of "VTube-LASER v2.8.4"
(→25px IMPROVED: REVERSE CALC) |
(→25px IMPROVED: REVERSE CALC) |
||
Line 48: | Line 48: | ||
The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.<br><br> | The part data on the right shows the first leg moving positive only in the Z axis. This is an example of data that could not be handled during reverse calculation.<br><br> | ||
The math engine has been improved to handle this condition. | The math engine has been improved to handle this condition. | ||
+ | <td> | ||
+ | [[image:vtube-laser_2.9.4_reverse calc.png|400px]] | ||
+ | </td> | ||
+ | <td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] NEW DATUM REPORTS POSSIBLE== | ||
+ | |||
+ | <table cellpadding=10 width=900> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Now VTube-LASER can show DATUM reports with Measured-aligned distances to MASTER Datums.<br><br> | ||
+ | <br><br> | ||
+ | To use these new report templates:<br><br> | ||
+ | # Download these two new templates: [https://www.advancedtubular.com/customers/vtube/vtubelaser_v2.9.4_datum_measured2master_report_templates.zip]* | ||
+ | # Extract them to a folder location that you can find. | ||
+ | # Load VTube-LASER. | ||
+ | # Go to Reports | ||
+ | # Click on the Templates tab. | ||
+ | # Click on Import. | ||
+ | # Find and click on the new Datum templates. | ||
+ | # Repeat for the second template file. | ||
+ | |||
<td> | <td> | ||
[[image:vtube-laser_2.9.4_reverse calc.png|400px]] | [[image:vtube-laser_2.9.4_reverse calc.png|400px]] |
Revision as of 00:00, 23 June 2017
Revision 2.8.4Original Release Date: June 22, 2017
|
Contents |
NEW: MULTISCREEN "SWITCH SCREEN" BUTTONS
When multiple screens are present, then VTube now adds "SWITCH SCREEN" buttons in the toolbars. |
IMPROVED: REVERSE CALC
In previous versions, when performing REVERSE CALC from bender data to centerline XYZ data, VTube-LASER could not keep the previous part orientation in 3D space when the first leg ran parallel to the Z axis. |
NEW DATUM REPORTS POSSIBLE
Now VTube-LASER can show DATUM reports with Measured-aligned distances to MASTER Datums.
|
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature